Related Experiment Video
Updated: Jan 27, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Exploring the detection of microcystin-LR using polar organic chemical integrative samplers (POCIS)
Michael J Brophy1, Allison L Mackie, Yuri Park
1Centre for Water Resources Studies, Faculty of Civil and Resource Engineering, Dalhousie University, 1360 Barrington Street, Halifax, NS B3H 4R2, Canada. graham.gagnon@dal.ca.
Abstract:
Polar organic chemical integrative samplers (POCIS) were used in this study to explore passive sampling for the detection of microcystin-LR (MC-LR). POCIS were deployed in triplicate for a minimum of 28 days at the inlet and outlet of a 1 km2, 4.2 km long lake in Atlantic Canada. POCIS results were compared to lake water grab sampling and followed a similar trend. Laboratory POCIS studies using lake water spiked with known MC-LR concentrations were used to estimate lake water concentrations over the deployment period by calculating POCIS sampling rate (Rs). The Rs for MC-LR in this lake water was found to be 0.045 (±0.001) and 0.041 (±0.001) L per day for initial concentrations of 0.5 and 1.0 μg L-1. Estimated MC-LR concentrations from POCIS were generally higher than grab sampling results, especially at the outlet to the lake from late September to late October. This could possibly give a better picture of MC-LR concentrations in the lake; MC-LR concentrations can fluctuate substantially over short time periods. POCIS were able to detect MC-LR in the water stream when grab sampling resulted in non-detects (i.e., below detection limit of LC-MS/MS). The use of passive sampling for MC-LR could have beneficial implications for public health and toxicity testing by lowering detection limits for this chronically and acutely toxic chemical. The correlation of aqueous MC-LR concentrations to POCIS MC-LR concentrations needs further study.
More Related Videos
07:18Natural Product Discovery with LC-MS/MS Diagnostic Fragmentation Filtering: Application for Microcystin Analysis
Published on: May 31, 2019
10:05Integrated Field Lysimetry and Porewater Sampling for Evaluation of Chemical Mobility in Soils and Established Vegetation
Published on: July 4, 2014
Related Concept Videos
Group Polarization
Molecular Shape and Polarity
Bond Polarity, Dipole Moment, and Percent Ionic Character
Chemical Reactions
Chemical Reactions Rearrange Atoms into New Substances
A chemical reaction takes starting materials—the reactants—and changes them...
Organic Compounds
Chemical Formulas