Related Experiment Video
Updated: Jan 27, 2026

Author Spotlight: Advancements in X-ray CT Tool Chain for Tree Core Analysis
Published on: September 22, 2023
Estimation and validation of the frequency responses of a scanner system and an image reconstruction system in X-ray
Kazuhiro Sato1, Ryota Kageyama2, Yu Tomita2
1Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan. satok@med.tohoku.ac.jp.
Abstract:
In computed tomography, factors that theoretically affect the modulation transfer function (MTF) in the region near the isocenter are the frequency responses of the scanner system (MTFS) and reconstruction processing (MTFA). Although MTFS and MTFA are performance indices that are not disclosed to the users, both can be estimated by the measured MTF with the use of theoretical formulas. In this study, we proposed two methods to obtain the MTFS and MTFA, and confirm their validity. The first method to obtain the MTFS and MTFA uses a theoretical formula and the measured MTF. Another method uses the measured MTF and the noise power spectrum. In both the methods, the MTFS and MTFA were obtained separately. By our proposed methods, performance indices that are not usually disclosed to the users can be known.
More Related Videos
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
09:37Extracting Metrics for Three-dimensional Root Systems: Volume and Surface Analysis from In-soil X-ray Computed Tomography Data
Published on: April 26, 2016
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Frequency Response of BJT
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...
Frequency Response of a Circuit
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
X-ray Imaging
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...