Related Experiment Video
Updated: Jan 27, 2026

Fecal micro RNA Isolation
Published on: October 28, 2020
Fecal Immunochemical Tests for Colorectal Cancer Screening: Is Fecal Sampling from Multiple Sites Necessary?
Efrat L Amitay1, Anton Gies2,3, Korbinian Weigl4,5,6
1Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany. e.amitay@dkfz-heidelberg.de.
Abstract:
Fecal immunochemical tests (FITs) for hemoglobin (Hb) are increasingly used for colorectal cancer (CRC) screening. Most FIT manufacturers instruct that fecal samples from multiple parts of one bowel movement should be obtained. Our aim was to compare the FIT diagnostic performance based on fecal samples from just one versus two different sites of one bowel movement. A total of 1141 participants of screening colonoscopy provided two fecal samples from two different sites of a single bowel movement for FIT analyses. There was no statistically significant difference in the diagnostic performance of the FIT when either one or both fecal samples were used for analysis, with area under the curve (AUC) for detecting CRC ranging from 0.94 (95% confidence interval (CI) 0.84⁻0.99) for one FIT to 0.95 (95%CI 0.86⁻0.99) for a geometric mean of two FITs. The manufacturers' recommendation of sampling multiple sites of the stool aims to reduce intra-individual Hb variability and improve diagnostic performance. If no such improvement can be achieved, the recommendation for multiple-site sampling might have potential adverse effects on population adherence to FIT-based CRC screening. Our results point to a potential of increasing adherence to FIT screening by simplifying instructions for fecal sampling at no loss of the diagnostic performance.
More Related Videos
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Conserved Binding Sites
Binding sites are often located in large pockets, and if their location on a protein’s surface is unknown, it can be predicted using various approaches. The energetic method computationally...
Conserved Binding Sites
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
Ligand Binding Sites
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...

