Related Experiment Video
Updated: Jan 27, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Measurement of Dorsal First Ray Mobility: A Topical Historical Review and Commentary
Ward M Glasoe1, Thomas C Michaud2
11 Division in Physical Therapy, Department of Rehabilitation Medicine, Medical School, University of Minnesota, Minneapolis, MN, USA.
Abstract:
Despite evidence that instability of the first ray (first metatarsal and medial cuneiform) alters the loading mechanics of the foot, surprisingly few studies have linked the condition with disorders of the foot. A factor limiting this research is the difficulty associated with measuring first ray mobility (FRM). To quantify dorsal FRM, clinicians and researchers have devised a variety of methods that impose a dorsally directed load, and record displacement. The methods include manual examination, radiographs, mechanical devices, and handheld rulers. Since different methods yield different results; each of these methods is worthy of scrutiny. This article reviews the methods used to quantify dorsal FRM and offers commentary on how the testing procedures could be standardized. The measurement of dorsal FRM informs surgical decisions, orthotic prescriptions, and research design strategies mostly as it pertains to the identification and treatment of first ray hypermobility. This review found sufficient support to recommend continued use of radiographs and mechanical devices for quantifying dorsal displacement, whereas measurements acquired with handheld rulers are prone to the same subjective error attributed to manual examination procedures. Since measures made with radiographs and existing mechanical devices have their own drawbacks, the commentary recommends ideas for standardizing the testing procedure and calls for the development of a next-generation device to measure dorsal FRM. This future device could be modeled after arthrometers that exist and are used to quantify stability at the knee and ankle. Level of Evidence: Level V, expert opinion.
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Radiological Investigation I: X-ray and CT

