Related Experiment Video
Updated: Jan 27, 2026

Trans-vivo Delayed Type Hypersensitivity Assay for Antigen Specific Regulation
Published on: May 2, 2013
Clinical characteristics of eperisone-induced immediate-type hypersensitivity
Bomi Shin1, Sun-Young Yoon2, Ji-Hyang Lee1
1Department of Allergy and Clinical Immunology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Background:
Eperisone is a commonly prescribed oral muscle relaxant, but few studies have been conducted of eperisone-induced hypersensitivity reactions.
Objective:
The purpose of this study was to investigate the clinical manifestations of eperisone-induced immediate-type hypersensitivity, and to evaluate the role of an intradermal test (IDT) in eperisone-induced anaphylaxis.
Methods:
This study was based on a retrospective review of medical records from 23 patients diagnosed as eperisone-induced immediate-type hypersensitivity with certain or probable causality. Intradermal tests were performed with a sterile 10 mg/mL eperisone solution.
Results:
Immediate-type hypersensitivity reactions to eperisone occurred within 15 minutes in 8.7%, within 30 minutes in 52.2%, and within 60 minutes in 82.6% of the patients, cumulatively. All patients showed cutaneous symptoms. Gastrointestinal symptoms were the second-most frequent (65.2%), respiratory symptoms (56.5%) followed, and cardiovascular symptoms were the least (39.1%). Nine (39.1%) patients were categorized as severe anaphylaxis. The mean onset time of severe anaphylaxis was 28.89 minutes, which was significantly shorter than non-severe anaphylaxis (p = 0.011). Five patients among the severe anaphylaxis group were evaluated with IDT, and all showed positive results. In contrast, all of the four patients who have done IDT among the moderate anaphylaxis group showed negative results. There was a significant relationship between severe anaphylaxis and positive IDT results (p = 0.008).
Conclusions:
Eperisone-induced immediate-type hypersensitivity is not uncommon in Korea, and the IDT could be a useful and safe diagnostic tool, especially in severe anaphylaxis.
Related Concept Videos
Hypersensitivities
Types of Hypersensitivities
Hypersensitivity reactions are categorized into four types: Type 1, Type 2, Type 3, and Type 4. Each type has a distinct mechanism...
Characteristics of Life
Characteristics of Fluids
Characteristics of Fluids
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...
Characteristics of JFET
The core of a JFET's operation is controlling drain current by modulating the gate-source voltage. When the drain and gate voltage are set to zero, the JFET exhibits no net current flow, representing a state of equilibrium. The drain current increases linearly as the...

