Related Experiment Video
Updated: Jan 27, 2026

Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Concomitant valve procedures in patients undergoing continuous-flow left ventricular assist device implantation: A
Tadahisa Sugiura1, Chitaru Kurihara2, Masashi Kawabori1
1Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, Tex; Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, Tex.
Objective:
Long-term support with continuous-flow left ventricular assist devices (CF-LVADs) has improved the outcomes of patients with end-stage heart failure. However, valve disease management in patients who undergo CF-LVAD implantation remains controversial. The aim of this study was to assess our single-center experience with patients who underwent a concomitant valve procedure during implantation of a CF-LVAD.
Methods:
From November 2003 through March 2016, 526 patients underwent primary CF-LVAD implantation with a HeartMate II (St Jude Inc, St Paul, Minn; n = 403) or HeartWare (Medtronic, Minneapolis, Minn; n = 123) device at our center. Of those, 91 underwent a concomitant valve procedure during implantation (CF-LVAD+valve procedure group), whereas 435 did not (CF-LVAD-only group). We compared preoperative characteristics and short-term and mid-term survival rates between these groups.
Results:
The concomitant valve procedures performed included 13 tricuspid valve repairs, 19 aortic valve repairs or replacements, 30 mitral valve repairs or replacements, and 29 double valve repairs or replacements. Survival rates at 1 month, 6 months, 12 months, and 24 months were 90.3%, 81.4%, 74.9%, and 67.4%, respectively, for the CF-LVAD-only group and 89.0%, 75.8%, 70.3%, and 65.9%, respectively, for the CF-LVAD+valve procedure group (P = .55). The results of Cox regression multivariable modeling showed that performing a concomitant valve procedure was not an independent predictor of mortality (hazard ratio, 1.29; 95% confidence interval, 0.96-1.74; P = .08).
Conclusions:
In our experience, performing a concomitant valve procedure during CF-LVAD implantation was not associated with an increased mortality rate. The decision to perform a concomitant valve procedure should be made primarily on the basis of clinical indications for the procedure.
Related Concept Videos
Patient-centered Care
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...
Center of Mass
The knowledge of the center of mass can also help us to describe and predict the motion of objects. For example, when a ball is thrown...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...