Counting Efficiencies Determined by Monte Carlo Methods for In Vivo Measurement of 131I Activity in Thyroid
MinSeok Park1,2, Tae-Eun Kwon1, Wi-Ho Ha1
1National Radiation Emergency Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea.
Abstract:
The counting efficiencies obtained using a physical neck phantom are typically used in the measurement of I activity in the thyroid. It is well known, however, that the geometrical discrepancies between the physical neck phantom and the anatomy of the subject can significantly influence the counting efficiencies. Thus, it is necessary to consider the anatomical characteristics of individuals if we need to accurately determine the activity of I in the thyroid. This study aims to produce individualized counting efficiencies for thyroid measurement, considering the age, sex, and overlying tissue thickness of the subject being measured by Monte Carlo simulation. Simulations were performed using a series of computational human phantoms of different ages and sexes. The difference in counting efficiencies, depending on the age and sex of the phantom, were found to range from -26 to 3% for the phantoms and monitoring systems considered in the present study. The overlying tissue thickness of the computational phantoms was also modified to find the relationship between the counting ratio of the 80.2 and 364 keV gammas from I and the overlying tissue thickness. The equations for estimating the overlying tissue thickness of a subject were then derived from the relationships between counting ratios and overlying tissue thickness. Finally, in the present study, a set of equations representing the variation in counting efficiencies for the 364 keV peak as a function of the overlying tissue thickness were derived, which can be used to determine individualized counting efficiencies for the subject being measured. These individualized counting efficiencies considering the overlying tissue thickness given a subject's age and sex can provide accurate estimates of I activity for internal dosimetry.
Related Concept Videos
The Thyroid Gland
The follicles have a central cavity lined by simple cuboidal to squamous epithelial cells called follicular cells. These cells produce the glycoprotein...
Functions of Thyroid Hormones
TH is indispensable for the normal development and maturation of the skeletal, muscular, and nervous systems during fetal and childhood growth. It facilitates bone mineral turnover and regulates protein synthesis in developing tissues, contributing significantly to overall growth and...
Co-activators and Co-repressors
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Dose Size and Dosing Frequency: Determination Methods
Dosage Interval and Administration Route: Determination Methods