Significant Reduction of Analysis Time with Bulk Sensors Operating in Nonequilibrium Mode
Andrey V Kalinichev1, Nadezhda V Pokhvishcheva1, Maria A Peshkova1
1Chemistry Institute , Saint Petersburg State University 26 Universitetskiy Prospect , 198504 Saint Petersburg , Russia.
Abstract:
The concept of reducing the analysis time with the bulk sensors operating in nonequilibrium mode is formulated theoretically and verified experimentally with ion-selective polymeric optodes. The influence of the measurement time on the optical response range, span, median, and sensitivity is calculated and demonstrated experimentally. Model aqueous samples are successfully analyzed using a nonequilibrium measurement protocol with conventional sodium-selective optodes and with pH optodes containing lipophilic organic electrolyte. The analysis time is significantly reduced from 300 to ca. 100 s, with sufficient recovery, reproducibility, and precision of the sample determination.
More Related Videos
08:32Development of Whispering Gallery Mode Polymeric Micro-optical Electric Field Sensors
Published on: January 29, 2013
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
Related Concept Videos
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Oxidation-Reduction Reactions
Bulk Modulus
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Bulk Density of Aggregate
Most natural mineral aggregates, like sand and gravel,...