Goniometric Measurement of Burn Scar Contracture: A Paradigm Shift Challenging the Standard
Ingrid Parry1, Reg Richard2, James K Aden3
1Department of Surgery, University of California, Davis, Sacramento.
Abstract:
Standard goniometry is the most commonly used method of assessing the range of motion (ROM) in patients with burn scar contracture. However, standard goniometry was founded on arthrokinematic principles and doesn't consider the cutaneous biomechanical influence between adjacent joint positions and skin pliability to accommodate motion. Therefore, the use of standard goniometry to measure burn scar contracture is called into question. This prospective, multicenter, comparative study investigated the difference between standard goniometry, based on arthrokinematics and a revised goniometry protocol, based on principles of cutaneokinematics and functional positions to measure ROM outcome in burn survivors. Data were collected for 174 joints from 66 subjects at seven burn centers totaling 1044 measurements for comparison. ROM findings using the revised protocol demonstrated significantly more limitation in motion 38.8 ± 15.2% than the standard protocol 32.1 ± 13.4% (p < .0001). Individual analyses of the motions likewise showed significantly more limitation with revised goniometry compared with standard goniometry for 9/11 joint motions. Pearson's correlation showed a significant positive correlation between the percentage of cutaneous functional units scarred and ROM outcome for the revised protocol (R2 = .05, p = .0008) and the Δ between the revised and standard protocols (R2 = .04, p = .0025) but no correlation was found with the standard goniometric protocol (R2 = .015, p = .065). The results of this study support the hypothesis that standard goniometry underestimates the ROM impairment for individuals whose motion is limited by burn scars. Having measurement methods that consider the unique characteristics of skin impairment and the impact on functional positions is an important priority for both clinical reporting and future research in burn rehabilitation.
Related Concept Videos
Measurement: Standard Units
Units and Standards of Measurement
Measurements of physical quantities are...
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
Standard Electrode Potentials
Standard Enthalpy of Formation
Calculating Standard Free Energy Changes