Related Experiment Video
Updated: Jan 27, 2026

Electroactive Polymer Nanoparticles Exhibiting Photothermal Properties
Published on: January 8, 2016
Strong Cathodoluminescence and Fast Photoresponse from Embedded CH3NH3PbBr3 Nanoparticles Exhibiting High Ambient
Joydip Ghosh, Ramesh Ghosh1, P K Giri
1Department of Physics and Astronomy , Seoul National University , Seoul 151747 , Republic of Korea.
Abstract:
This study presents a comprehensive analysis of the strong cathodoluminescence (CL), photoluminescence (PL), and photoresponse characteristics of CH3NH3PbBr3 nanoparticles (NPs) embedded in a mesoporous nanowire (NW) template. Our study revealed a direct correlation between the CL and PL emissions from the perovskite NPs (Per NPs), for the first time. Per NPs are fabricated by a simple spin-coating of a perovskite precursor on the surface of metal-assisted chemically etched mesoporous Si NW arrays. The Per NPs confined in the mesopores show blue-shifted and enhanced CL emission as compared to the bare perovskite film, while the PL intensity of Per NPs is dramatically high compared to that of their bulk counterpart. A systematic analysis of the CL/PL spectra reveals that the quantum confinement effect and ultralow defects in Per NPs are mainly responsible for the enhanced CL and PL emissions. Low-temperature PL and time-resolved PL analysis confirm the high exciton binding energy and radiative recombination in Per NPs. The room temperature PL quantum yield of the Per NP film on the NW template was found to be 40.5%, while that of Per film was 2.8%. The Per NPs show improved ambient air stability than the bare film due to the protection provided by the dense NW array, since a dense NW array can slow down the lateral diffusion of oxygen and water molecules in Per NPs. Interestingly, the Si NW/Per NP junction shows superior visible light photodetection and the prototype photodetector shows a high responsivity (0.223 A/W) with response speeds of 0.32 and 0.28 s of growth and decay in photocurrent, respectively, at 2 V applied bias, which is significantly better than the reported photodetectors based on CH3NH3PbBr3 nanostructures. This work demonstrates a low-cost fabrication of CH3NH3PbBr3 NPs on a novel porous NW template, which shows excellent photophysical and optoelectronic properties with superior ambient stability.
Related Concept Videos
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:

