A New Water Level Measurement Method Combining Infrared Sensors and Floats for Applications on Laboratory Scale Channel under Unsteady Flow Regime
Related Experiment Video
Updated: Jan 27, 2026

Operation of Laboratory Photobioreactors with Online Growth Measurements and Customizable Light Regimes
Published on: October 28, 2021
Samer Majdalani1, Jean-Philippe Chazarin2, Roger Moussa3
1Laboratoire HydroSciences Montpellier, Centre National de la Recherche Scientifique, Institut de Recherche pour le Développement, Université de Montpellier, 34090 Montpellier, France. samer.majdalani@umontpellier.fr.
Abstract:
In this paper, we studied water transport under an unsteady flow regime in an experimental channel (4 m in length; 3 cm in width). Our experiments implicated some measuring requirements, specifically, a water level (WL) detection technique that is able to measure WL in a range of 2 cm with a precision of 1 mm. The existing WL detection techniques could not meet our measurement requirements. Therefore, we propose a new measurement method that combines two approaches: An "old" water contact technique (float) with a "new" remote non-contact technique (infrared sensor). We used an extruded polystyrene (XPS Foam) that needed some adequate treatment before using it as float in experimental measurements. The combination of IR-sensors with treated float foam lead to a sensitive measurement method that is able to detect flat and sharp flow signals, as well as highly dynamic variations of water surface level. Based on the experimental measurements of WL and outflow at the channel output, we deduced a loop rating curve that is suitable with a power law adjustment. The new measurement method could be extended to larger scale applications like rivers and more complicated cross section geometry of irregular shape.
Related Concept Videos
Velocity and Acceleration in Steady and Unsteady Flow
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
Uniform Depth Channel Flow
Energy Considerations in Open Channel Flow
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Uniform Depth Channel Flow: Problem Solving