A New Water Level Measurement Method Combining Infrared Sensors and Floats for Applications on Laboratory Scale

Samer Majdalani1, Jean-Philippe Chazarin2, Roger Moussa3

  • 1Laboratoire HydroSciences Montpellier, Centre National de la Recherche Scientifique, Institut de Recherche pour le Développement, Université de Montpellier, 34090 Montpellier, France. samer.majdalani@umontpellier.fr.

Related Concept Videos

Velocity and Acceleration in Steady and Unsteady Flow01:11

Velocity and Acceleration in Steady and Unsteady Flow

In fluid mechanics, velocity and acceleration are key concepts for analyzing particle motion in both steady and unsteady flow. Consider a fluid particle moving along a pathline, where its velocity depends on its position and time. The particle's acceleration is obtained by differentiating the velocity with respect to time.
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
408
Uniform Depth Channel Flow01:27

Uniform Depth Channel Flow

Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...
549
Energy Considerations in Open Channel Flow01:27

Energy Considerations in Open Channel Flow

Open channel flow, where a fluid flows with a free surface exposed to the atmosphere, is primarily governed by gravitational and surface effects, distinguishing it from closed conduit or pipe flow. In open channels such as rivers, canals, and artificial channels, energy analysis provides valuable insights into flow behavior and the relationship between depth, velocity, and slope.Specific Energy and Flow DepthIn open channel flow, the specific energy, E, combines the gravitational potential...
594
Ratio Level of Measurement00:54

Ratio Level of Measurement

The way a set of data is measured is called its level of measurement. Correct statistical procedures depend on a researcher being familiar with levels of measurement. For analysis, data are classified into four levels of measurement—nominal, ordinal, interval, and ratio.
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
21.0K
Ion Channels01:19

Ion Channels

The movement of ions like sodium, potassium, and calcium into and out of the cell is essential to maintain the electrochemical gradient in living cells. The ion channels—a class of membrane transport proteins—help maintain this ionic gradient for the smooth functioning of physiological activities such as maintaining cell size and volume, conducting nerve impulses, and gas and nutrient exchange.
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
91.3K
Uniform Depth Channel Flow: Problem Solving01:18

Uniform Depth Channel Flow: Problem Solving

To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by...
473