Pilot evaluation of refractive prediction errors associated with a new method for ray-tracing-based intraocular lens
Nino Hirnschall1, Tobias Buehren2, Micheal Trost3
1Vienna Institute for Research in Ocular Surgery, a Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.
Purpose:
To investigate the accuracy of a new ray-tracing-based intraocular lens (IOL) power calculation method and to compare the outcomes with different IOL calculation formulas.
Setting:
Hanusch Hospital, Vienna, Austria.
Design:
Theoretical prospective monocentric study.
Methods:
Monofocal aspheric plate haptic IOL (CT Asphina 409M/MP) implantation was performed in 40 cataractous eyes. At 1 month postoperatively, manifest refraction and optical coherence tomography-based biometry (IOLMaster 700) was conducted. The refractive spherical equivalent absolute error of the ray-tracing IOL power calculation method, based on individualized eye model data, a physical lens position predictor, retinal image quality metrics criteria for IOL power selection, and exact IOL design information was calculated and compared with the outcomes using the Barrett Universal II, Hill-RBF, SRK/T, and Haigis formulas.
Results:
There was no significant difference in absolute error between ray tracing and the Barrett Universal II (0.37 diopter [D] ± 0.29 [SD]; P = .601) or Hill-RBF (0.39 ± 0.31 D; P = .170). However, the absolute error was significantly lower compared with the Haigis formula (0.42 ± 0.36 D; P = .029) and SRK/T (0.52 ± 0.39 D; P = .020). The refractive prediction of absolute error within ±0.25 D and within ±0.50 D ranged between 48% (ray tracing) and 25% (SRK/T), and between 80% (ray tracing) and 55% (SRK/T), respectively.
Conclusions:
The new ray-tracing-based IOL power calculation method was an accurate procedure and showed promising preliminary results not only for the refractive outcome, but also for surgeon and patient education as well as the management of patient expectations.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Fundamental Attribution Error
Pilot and Numeric Relaying
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...