Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Periprosthetic biomechanical response towards dental implants, with functional gradation, for single/multiple dental
Subhomoy Chatterjee1, Sulagna Sarkar2, Surya R Kalidindi3
1Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India.
Abstract:
The differences in shape and stiffness of the dental implants with respect to the natural teeth (especially, dental roots) cause a significant alteration of the periprosthetic biomechanical response, which typically leads to bone resorption and ultimately implant loosening. In order to avoid such clinical complications, the implant stiffness needs to be appropriately adapted. In this study, hollow channels were virtually introduced within the designed implant screws for reduction of the overall stiffness of the prototype. In particular, two opposing radial gradients of increasing hollow channel diameters, i.e., outside to inside (Channel 1) and inside to outside (Channel 2) were considered. Two clinical situations of edentulism were addressed in this finite element-based study, and these include a) loss of the first molar, and b) loss of all the three molars. Consequently, two implantation approaches were simulated for multiple teeth loss - individual implantation and implant supported dental bridge. The effects of implant length, approach and channel distribution on the biomechanical response were evaluated in terms of the von Mises stress within the interfacial periprosthetic bone, under normal masticatory loading. The results of our FE analysis clearly reveal significant variation in periprosthetic bone stress between the different implant designs and approaches. An implant screw length of 11 mm with the Channel 2 configuration was found to provide the best biomechanical response. This study also revealed that the implant supported dental bridge approach, which requires lower bone invasion, results in favorable biomechanical response in case of consecutive multiple dental loss.
Related Concept Videos
Design Example: Aggregate Gradation
The grading, or particle-size distribution, of sand is determined using sieve analysis, with standard sizes ranging from 150 μm to 10 mm (ASTM No. 100 sieve to 3⁄8 in. sieve). Sand is...
Loss of Tumor Suppressor Gene Functions
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Bioavailability Study Design: Single Versus Multiple Dose Studies
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...