Related Experiment Video
Updated: Jan 27, 2026

Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
Identification of fishy odor causing compounds produced by Ochromonas sp. and Cryptomonas ovate with gas
Qingyuan Guo1, Jianwei Yu2, Yunyun Zhao3
1Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Yancheng Institute of Technology, Yancheng, Jiangsu Province 224051, China.
Abstract:
Disgusting fishy odor problems have become a major concern in drinking water quality, and are commonly related to algal proliferation in source water. Unlike the typical musty/earthy odorants 2-methylisoborneol (MIB) and geosmin, identification of the corresponding fishy odorants is still a big challenge. In this study, two species of fishy-odor-producing algae, Ochromonas sp. and Cryptomonas ovate, were cultured to explore the odor production characteristics and typical odorants. When algae were ruptured in the stationary and decline phases, fishy odor intensities of 4 to 8 characterized by FPA were produced. However, some frequently reported aldehydes that could cause fishy odor, including n-hexanal, 2-octenal, heptanal, 2,4-heptanal and 2,4-decadienal, were not detected in either of the cultured algae. The possible fishy odor-causing compounds were further identified by combining gas chromatography-olfactometry (GC-O/MS) and comprehensive two-dimensional gas chromatography (GC × GC-TOFMS) using retention indices (RIs). From GC-O/MS analysis, twelve and six olfactometry peaks with various odor characteristics were identified in Ochromonas sp. and Cryptomonas ovate, respectively, of which three and two olfactometry peaks showed fishy odor characteristics. 2-Nonenal, 2,4-octadienal, fluorene and 2-tetradecanone were identified as fishy odorants in Ochromonas sp., and 1-octen-3-ol, 6-methyl-5-hepten-2-one, 1-octen-3-one, 2-nonenal and 2,4-octadienal were identified in Cryptomonas ovate. Other identified compounds, including butyl butanoate (fragrant odor), ionone (fragrant odor), bis (2-chloroisopropyl) ether (chemical odor) etc., did not show fishy features. Therefore, the fishy odor might be a synthetic and comprehensive odor, which resulted from the combination of different odorants and their synergistic effects. The results of this study will be helpful for understanding fishy odor problems, which will provide support for fishy odor management and control in the drinking water industry.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
09:49Identification of Olfactory Volatiles using Gas Chromatography-Multi-unit Recordings GCMR in the Insect Antennal Lobe
Published on: February 24, 2013
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....