Volume-rendered computed tomography images of the surgical field for endolymphatic sac surgery
Shinya Miuchi1,2, Masahiro Komori3,4, Jun Hyodo3
1Department of Otolaryngology, Takanoko Hospital, Matsuyama, Ehime, Japan. s-miuchi@hyo-med.ac.jp.
Purpose:
Identification of the endolymphatic sac has failed occasionally. Postoperative complications have also rarely been reported. Given a safer and more reliable surgery, preoperative anatomical assessments are valuable, however, the vestibular aqueduct has seldom been seen with multi-planar reconstruction (MPR) computed tomography (CT) images yet. Our study aimed to determine the significance and utility of volume-rendered (VR) CT images of the surgical field for identifying the vestibular aqueduct, compared with MPR CT images.
Subjects And Methods:
14 patients with Meniere's disease who underwent endolymphatic sac surgery between 2008 and 2011. Location and size of the vestibular aqueduct were assessed using VR and MPR CT images, independently.
Results:
Accuracy of identifying the location differed significantly between VR and MPR CT images (rate of total correct evaluations: 100% by VR CT images vs 75% by MPR CT images, p = 0.02). Size was correctly identified in cases with a small endolymphatic sac using VR CT images (rate of total correct evaluations for size of the vestibular aqueduct: 100% by VR CT vs 57% by MPR CT, p = 0.046). VR CT images also demonstrated clearly the relationship between the endolymphatic sac and high jugular bulb. In two cases, the endolymphatic sac was identified by VR images, not by MPR images.
Conclusion:
Accurate information about the location and size of vestibular aqueduct can allow sac surgeons to identify a tiny endolymphatic sac more easily and certainly, and also aids surgical trainees to learn sac surgery safely.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Constant Volume Calorimetry
Volume of Distribution
Work Done During Volume Change
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as