Related Experiment Video
Updated: Jan 27, 2026

Cereal Crop Ear Counting in Field Conditions Using Zenithal RGB Images
Published on: February 2, 2019
Evaluation of dose calculation algorithms using different density materials for in-field and out-of-field conditions
1Radiological Sciences Department, College of Applied Medical Science, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia.
Aim:
The accuracy of the dose calculation is vital in the stereotactic ablative body radiotherapy (SABR) technique to achieve clinically effective dose distribution for better tumor control. Multiple commercial radiotherapy treatment planning systems (TPS) were implemented with different algorithms, such as Acuros XB in Eclipse and Superposition in XiO. The aim of this study is to investigate five different dose calculation algorithms, namely, pencil beam convolution (PBC), Acuros XB, AAA implemented in an Eclipse system, collapsed cone convolution (CCC) algorithm implemented in Mobius3D and superposition algorithms implemented in the XiO system, and then validate the results against measurements using an Institute of Physical Sciences in Medicine (IPSM) phantom with different density materials for in-field and out-of- field conditions.
Material And Methods:
The IPSM phantom was used to investigate the dose calculation algorithm performances in four different densities (water, lung, ribs, and dense bone) using different beam configurations, including small beam fields utilised in lung SABR. Five commercial algorithms implemented in two TPS (Eclipse and XiO) and one plan check (M3D) system were used for in-field and out-of-field measurement.
Results:
In the in-field condition, the Acuros XB algorithm had lower mean differences than the measured dose by the IC ranging from -0.46 to 0.24 for all the densities. In the out-of-field condition, the results of eclipse system: AAA, PBC and Acuros XB algorithms demonstrated underdose point's measurements by -40% for all densities except for AAA calculations in lung density (overdosed by 40%). The measured points of the superposition algorithms were overestimated to the actual dose less than 30% in water, lung and dense bone. At the same densities, the CCC algorithms showed relatively the lowest differences in percentage compared to the superposition algorithms.
Conclusion:
Our results showed that the Acuros XB and superposition algorithms are closer to the actual measured dose than AAA, PBC and CCC for majority of the field conditions for water-equivalent, lung, rib and dense bone densities. The CCC algorithm resulted in a better agreement with the measurement of the out-of-field points compared with the other algorithms.
Related Concept Videos
Electric Field
In the new picture, imagine that the first charge sets up an electric field independent of all other charges in the universe. When another charge comes in its vicinity, the second charge experiences an electric force depending on the electric field at that point. The source charge does not...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Electromagnetic Fields
However, the observation of...
Field Effect Transistor
Crystal Field Theory - Octahedral Complexes
To explain the observed behavior of transition metal complexes (such as colors), a model involving electrostatic interactions between the electrons from the ligands and the electrons in the unhybridized d orbitals of the central metal atom has been developed. This electrostatic model is crystal field theory (CFT). It helps to understand, interpret, and predict the colors, magnetic behavior, and some structures of coordination compounds of transition metals.
CFT focuses on...
Electric Field Lines
The solution to this problem is to use electric field lines, which are not vectors but...