Related Experiment Video
Updated: Jan 27, 2026

Phase Contrast Magnetic Resonance Imaging in the Rat Common Carotid Artery
Published on: September 5, 2018
Quantitative phase contrast MRI of penetrating arteries in centrum semiovale at 7T
1Department of Radiology and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA.
Abstract:
Pathological changes of penetrating arteries (PA) within the centrum semiovale is an important contributing factor of cerebral small vessel disease (SVD). However, quantitative characterization of the PAs remains challenging due to their sub-voxel sizes. Here, we proposed a Model-based Analysis of Complex Difference images (MACD) of phase contrast MRI capable of measuring the mean velocities (vmean), diameters (D), and volume flow rates (VFR) of PAs without contamination from neighboring static tissues at 7 T. Simulation, phantom and in vivo studies were performed to evaluate the reproducibility and errors of the proposed method. For comparison, a Model-based Analysis of Phase difference images (MAP) was also carried out in the simulation. The proposed MACD analysis approach was applied in vivo to study the age dependence of PA properties in healthy subjects between 21 and 55 years old. Simulation showed that our proposed MACD approach yielded smaller errors than MAP, with errors increasing at lower velocities and diameters for both methods. In the phantom study, errors of the MACD-derived vmean, D, and VFR were ≤20% of their true values when vmean≥1cm/s and similar at different spatial resolutions. On the other hand, errors of the uncorrected apparent velocities were 24-60% and depended strongly on voxel size. The MACD errors linearly increased with the angle (α) between the vessel and slice normal direction at α ≤ 2° but remained almost constant at larger α. Results of the in vivo studies showed that the coefficients of repeatability for vmean, D, and VFR for PAs with α = 0° were 0.67 cm/s, 0.060 mm, and 0.067 mm3/s, respectively. No significant age dependence was found for the number, vmean, D, and VFR of PAs. The mean vmean, D, and VFR over all PAs with α = 0° were 1.79 ± 0.62 cm/s, 0.17 ± 0.05 mm, and 0.36 ± 0.18 mm3/s, respectively. Quantitative measurements of PAs with the MACD method may serve as a useful tool for illuminating the vascular pathology in cerebral SVD.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Phase Diagrams
Phase Transitions
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Phase Changes
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...

