Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

9.2K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.2K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

249
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
249
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

1.2K
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Nuclear Magnetic Resonance (NMR): Overview01:07

Nuclear Magnetic Resonance (NMR): Overview

6.8K
Nuclear magnetic resonance (NMR) is a phenomenon exhibited by certain nuclei that can absorb characteristic radio frequency radiation under certain conditions. NMR has been extensively applied in molecular spectroscopy and medical diagnostic imaging. In both these applications, the molecule or subject under study is placed in a magnetic field and irradiated with radio frequency energy.
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
6.8K
Resonance02:52

Resonance

64.9K
The Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N-O and N=O bonds.
64.9K
Colors and Magnetism03:02

Colors and Magnetism

14.0K
Color in Coordination Complexes
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
14.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Should perilymph be considered when modeling the lateral semicircular canal?

Biomechanics and modeling in mechanobiology·2026
Same author

Office-Based Middle Ear Surgery Under Local Anesthesia: A Contemporary Review.

Journal of clinical medicine research·2025
Same author

High prevalence of sleep disorders in Ménière's disease: Interplay between vestibular function and sleep.

Journal of vestibular research : equilibrium & orientation·2025
Same author

Deciphering <sup>18</sup>F-DOPA uptake in SDH-related head and neck paragangliomas: a radiomics approach.

Journal of endocrinological investigation·2024
Same author

Breaking barriers in inner ear MRI: The changing role of deep learning reconstruction.

Diagnostic and interventional imaging·2024
Same author

[<sup>68</sup>Ga]DOTATOC PET-derived radiomics to predict genetic background of head and neck paragangliomas: a pilot investigation.

European journal of nuclear medicine and molecular imaging·2024

Related Experiment Video

Updated: Jan 27, 2026

Robotic Cochlear Implantation for Direct Cochlear Access
08:06

Robotic Cochlear Implantation for Direct Cochlear Access

Published on: June 16, 2022

4.0K

Magnetic resonance imaging after cochlear implants.

Naif Bawazeer1, Hella Vuong2, Sophie Riehm3

  • 1Department of Otolaryngology-Head & Neck Surgery, Umm Al-Qura University, Saudi Arabia.

Journal of Otology
|April 3, 2019
PubMed
Summary

Cochlear implants (CIs) can cause adverse events during MRI scans, including magnet displacement and pain. Careful patient positioning and protective measures are crucial to mitigate risks during magnetic resonance imaging with CIs.

Keywords:
Cochlear implantMRIRisk

More Related Videos

Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
07:00

Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process

Published on: June 21, 2024

1.5K
Cochlear Implantation in the Guinea Pig
09:56

Cochlear Implantation in the Guinea Pig

Published on: June 15, 2018

11.8K

Related Experiment Videos

Last Updated: Jan 27, 2026

Robotic Cochlear Implantation for Direct Cochlear Access
08:06

Robotic Cochlear Implantation for Direct Cochlear Access

Published on: June 16, 2022

4.0K
Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
07:00

Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process

Published on: June 21, 2024

1.5K
Cochlear Implantation in the Guinea Pig
09:56

Cochlear Implantation in the Guinea Pig

Published on: June 15, 2018

11.8K

Area of Science:

  • Otolaryngology
  • Radiology
  • Biomedical Engineering

Background:

  • Cochlear implants (CIs) are generally MRI-compatible up to 3 Tesla (T).
  • Despite compatibility, risks of adverse events like implant displacement during MRI exist.
  • Literature reports include cases of accidents with compatible CI systems.

Purpose of the Study:

  • To report adverse events in patients with cochlear implants undergoing MRI.
  • To highlight the importance of safety protocols during MRI examinations for CI patients.

Main Methods:

  • Retrospective case series of six patients with cochlear implants who underwent MRI.
  • Detailed reporting of three cases experiencing adverse events.
  • Analysis of MRI artifacts across different imaging sequences.

Main Results:

  • Three patients experienced adverse events: magnet displacement with partial demagnetization, total demagnetization requiring reimplantation, and severe pain disrupting the scan.
  • 3D MRI angiography produced the smallest artifacts.
  • Diffusion and T2 FLASH sequences resulted in the largest artifacts.

Conclusions:

  • Supervised patient transfer into the MRI scanner by specialists is essential.
  • Maintaining a specific angle (≤90°) between implant and MRI magnetic fields (B0) is critical.