Related Experiment Video
Updated: Jan 27, 2026

Longitudinal Evaluation of Mouse Hind Limb Bone Loss After Spinal Cord Injury using Novel, in vivo, Methodology
Published on: December 7, 2011
Is the Bare Spot reliable for the bone loss measurement?
Max Rogerio Freitas Ramos1, Yonder Archanjo Ching San Junior1, Luiz Henrique Pereira Alves2
1Department of Orthopaedic Surgery, Universidade Federal do Estado do Rio de Janeiro, Rio de Janeiro, Rio de Janeiro, Brazil.
The Bare Spot (BS) is a reliable landmark for assessing glenoid bone loss in shoulder instability, but requires a correction factor due to its anterior positioning. Arthroscopic measurements proved accurate for evaluating shoulder joint bone defects.
Area of Science:
- Orthopedic Surgery
- Anatomy
- Biomechanics
Background:
- Assessing bone loss in anterior shoulder instability is crucial for surgical planning.
- The Bare Spot (BS) is a proposed anatomical landmark for intra-operative glenoid bone defect evaluation.
- Reliability of the BS for defining bone loss requires validation.
Purpose of the Study:
- To evaluate the reliability of the Bare Spot (BS) as an anatomical landmark for intra-operative definition of bone loss in anterior shoulder instability.
Main Methods:
- Measurements of distances from the BS to glenoid margins (anterior, posterior, inferior) were taken.
- Both arthroscopic visualization and open surgical approaches were utilized in 20 shoulders.
- Comparison of measurements between arthroscopic and open methods assessed reliability.
Main Results:
- The BS did not consistently align with the glenoid center; BS-P distance exceeded BS-A distance (p < 0.05).
- The BS was located approximately 40% closer to the anterior glenoid margin.
- A correction factor (BS-A × 1.25 / BS-P = 1) was proposed to account for anterior positioning.
Conclusions:
- The BS is positioned 40% of the joint diameter from the anterior glenoid margin, necessitating a correction factor for accurate use.
- The BS can serve as a valuable landmark in shoulder instability surgery when its anterior bias is considered.
- Arthroscopy demonstrated reliability for obtaining accurate bone measurements within the shoulder joint.
More Related Videos
Related Concept Videos
Reliability and Validity
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...

