Related Experiment Video
Updated: Jan 26, 2026

Using Microwave and Macroscopic Samples of Dielectric Solids to Study the Photonic Properties of Disordered Photonic Bandgap Materials
Published on: September 26, 2014
Real Time Microwave Biochemical Sensor Based on Circular SIW Approach for Aqueous Dielectric Detection
Amyrul Azuan Mohd Bahar1, Z Zakaria2, M K Md Arshad3,4
1Microwave Research Group, Centre for Telecommunication Research and Innovation (CeTRI), Faculty of Electronics and Computer Engineering, Universiti Teknikal Malaysia Melaka (UTeM), 76100, Durian Tunggal, Melaka, Malaysia.
Abstract:
In this study, a critical evaluation of analyte dielectric properties in a microvolume was undertaken, using a microwave biochemical sensor based on a circular substrate integrated waveguide (CSIW) topology. These dielectric properties were numerically investigated based on the resonant perturbation method, as this method provides the best sensing performance as a real-time biochemical detector. To validate these findings, shifts of the resonant frequency in the presence of aqueous solvents were compared with an ideal permittivity. The sensor prototype required a 2.5 µL volume of the liquid sample each time, which still offered an overall accuracy of better than 99.06%, with an average error measurement of ±0.44%, compared with the commercial and ideal permittivity values. The unloaded Qu factor of the circular substrate-integrated waveguide (CSIW) sensor achieved more than 400 to ensure a precise measurement. At 4.4 GHz, a good agreement was observed between simulated and measured results within a broad frequency range, from 1 to 6 GHz. The proposed sensor, therefore, offers high sensitivity detection, a simple structural design, a fast-sensing response, and cost-effectiveness. The proposed sensor in this study will facilitate real improvements in any material characterization applications such as pharmaceutical, bio-sensing, and food processing applications.
Related Concept Videos
Chemical Reactions in Aqueous Solutions
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):
Capacitor With A Dielectric
Dielectrics are non-conducting materials with no free or loosely bound electrons. When a dielectric is...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Gauss's Law in Dielectrics
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...