A Comparison Among Different Automatically Segmented Slabs to Assess Neovascular AMD using Swept Source OCT
Mariacristina Parravano1, Enrico Borrelli2,3, Riccardo Sacconi2
1IRCCS - Fondazione Bietti, Rome, Italy.
The RPE-RPE fit optical coherence tomography angiography (OCTA) slab provides the best agreement for assessing neovascularization (NV) in age-related macular degeneration (AMD). This method offers higher reproducibility and larger measurements for type 1 NV lesions.
Area of Science:
- Ophthalmology
- Medical Imaging
- Retinal Diseases
Background:
- Age-related macular degeneration (AMD) is a leading cause of vision loss.
- Neovascularization (NV) is a key feature of AMD, driving disease progression.
- Optical coherence tomography angiography (OCTA) is a crucial imaging modality for NV assessment.
Purpose of the Study:
- To systematically compare intermodality and interreader agreement for AMD-associated NV assessment using OCTA images from different slabs.
- To evaluate the reproducibility of NV measurements across various OCTA image reconstructions.
Main Methods:
- Data from 48 patients (50 eyes) with AMD and type 1 or 2 NV were analyzed.
- Swept source (SS)-OCTA was used to acquire images.
- Three OCTA en face image slabs were generated: outer retina to choriocapillaris (ORCC), choriocapillaris (CC), and retinal pigment epithelium (RPE)-RPE fit.
- Two readers assessed interreader variability; single images assessed intermodality variability.
Main Results:
- The RPE-RPE fit slab demonstrated the highest interreader reproducibility for type 1 NV assessment (lowest mean absolute difference: 0.16 mm²).
- Intraclass correlation coefficient (ICC) and coefficient of repeatability (CR) confirmed superior reproducibility with the RPE-RPE fit slab.
- Type 1 NV measurements were significantly larger on RPE-RPE fit images (0.62 mm²) compared to CC images (0.00 mm²) and comparable to ORCC images (0.58 mm²).
Conclusions:
- Retinal pigment epithelium (RPE)-RPE fit OCTA images offer the highest interreader agreement for neovascularization assessment in AMD.
- This imaging slab provides more accurate and reproducible measurements of type 1 NV lesions.
- OCTA imaging holds potential for use in clinical trials evaluating novel treatments for NV.
More Related Videos
Related Concept Videos
Sources of Self-Esteem III: Social Comparison
Automatic Processing and Automatic Social Behavior
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...