Purpose:
We systematically compare the intermodality and interreader agreement in age-related macular degeneration(AMD)-associated neovascularization assessment for optical coherence tomography angiography (OCTA) images obtained using different slabs.
Methods:
We collected data from 48 patients (50 eyes) with type 1 or 2 neovascularization (NV) and AMD. Subjects were imaged with a swept source (SS)-OCTA system. For each eye, three OCTA en face images generated from three different slabs were exported: (1) the outer retina to choriocapillaris (ORCC) image, (2) the choriocapillaris (CC) image, and (3) the retinal pigment epithelium (RPE)-RPE fit image. Each image was graded by two readers to assess interreader variability and a single image for each modality was used to assess the intermodality variability.
Results:
In the assessment of type 1 NV, mean absolute interreader difference between measured NV areas was 0.19, 0.30, and 0.16 mm2 for ORCC, CC, and RPE-RPE fit images, respectively. Similarly, the coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) indicated that the RPE-RPE fit assessment was characterized by the highest interreader reproducibility. Type 1 NV size was 0.58 mm2 (0.30-1.60 mm2) on ORCC images, 0.00 mm2 (0.00-0.36 mm2) on CC images (P = 0.002 vs. ORCC), and 0.62 mm2 (0.31-2.03 mm2) on RPE-RPE fit images (P < 0.0001 vs. CC, P = 0.041 vs. ORCC).
Conclusions:
The RPE-RPE fit OCTA images have the highest interreader agreement and deliver larger measurements in type 1 lesions.
Translational Relevance:
OCTA imaging may be used in ongoing trials of potential novel treatments for NV.
More Related Videos
Related Concept Videos
Sources of Self-Esteem III: Social Comparison
Automatic Processing and Automatic Social Behavior
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...