Related Experiment Video
Updated: Jan 26, 2026

Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
Mapping the site-specific accuracy of loop-based local pulse wave velocity estimation and reflection magnitude: a 1D
Daimé Campos Arias1,2,3, Nikos Stergiopulos4, Tania Rodríguez Moliner2
1IBiTech-bioMMeda, Ghent University, Ghent, Belgium.
Objective:
Local pulse wave velocity (PWV) can be estimated from the waterhammer equation and is an essential component of wave separation analysis. However, previous studies have demonstrated inaccuracies in the estimations of local PWV due to the presence of reflections. In this study we compared the estimates of local PWV from the PU-loop, ln(D)U-loop, QA-loop and ln(D)P-loop methods along the complete human arterial tree, and analyzed the impact of the estimations on subsequent wave separation analysis.
Approach:
Estimated values were derived from the numerical outputs (pressure, flow, flow velocity, area and diameter waveforms) of a 1D model of the human circulation, and compared against a reference PWV obtained from the Bramwell-Hill equation in a reference configuration, and in a configuration with lower distensibility representing ageing.
Main Results:
When including all nodes, the overall performance of the methods was poor (correlations and mean differences of R 2 < 0.4 and 3.0 ± 4.1 m s-1 for the PU-loop, R 2 < 0.07 and -0.7 ± 2.3 m s-1 for the ln(D)U-loop, and R 2 < 0.06 and -0.4 ± 2.3 m s-1 for the QA-loop). Focusing on specific sites, the ln(D)U- and QA-loop methods yielded acceptable results in the thoracic aorta and iliac arteries, while the PU-loop method was acceptable at the aortic arch. The reflection-insensitive ln(D)P-loop method performed well over the complete network (R 2 = 0.9 and 0.3 ± 0.3 m s-1), as did a previously proposed reflection-correction method for most vascular sites. Large errors in PWV estimation are attenuated in subsequent wave separation analysis, but the errors are site-dependent.
Significance:
We conclude that the performances of the PU-loop, ln(D)U-loop and QA-loop methods are highly site-specific. The results should be interpreted with caution at all times.
Related Concept Videos
Reflection of Waves
Velocity and Acceleration of a Wave
The velocity of the particles can be obtained by taking the partial derivative of the position equation with respect to time....
Improving Translational Accuracy
Orders of Magnitude
The order of magnitude is simply a way of rounding numbers consistently to the nearest power of 10. This makes doing rough mental math...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...

