Related Experiment Video
Updated: Jan 26, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
A single-use, size-specific, nylon arthroplasty guide: a preliminary study for hip resurfacing
Keisuke Uemura1,2, Oliver R Boughton1, Kartik Logishetty1
1MSk Laboratory, Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, UK.
A new single-use nylon guide improved accuracy in hip resurfacing arthroplasty compared to conventional guides. This guide offers better precision for component positioning, potentially reducing complications in arthroplasty surgery.
Area of Science:
- Orthopaedic Surgery
- Biomedical Engineering
- Surgical Navigation
Background:
- Accurate component positioning is critical in arthroplasty to prevent complications.
- Conventional surgical guides can be prone to errors and require significant surgeon experience.
- A novel single-use, size-specific nylon guide was developed to enhance accuracy without increasing costs.
Purpose of the Study:
- To evaluate the effectiveness of a single-use nylon guide in improving accuracy for hip resurfacing arthroplasty.
- To compare the precision of a single-use nylon guide against a conventional metal guide.
- To assess accuracy in terms of anteversion, inclination, and insertion point.
Main Methods:
- 66 synthetic femurs with osteoarthritic morphology were used.
- Three surgeons performed drilling for the femoral component using either the single-use nylon guide or a conventional guide.
- Measurements of anteversion, inclination, and insertion point were compared to a computer-based plan.
Main Results:
- The single-use nylon guide achieved significantly better accuracy for anteversion (p=0.03) and insertion point (p<0.001) compared to the conventional guide.
- Anteversion was closer to the plan with the nylon guide (6.7°) than the conventional guide (4.3°).
- Insertion point accuracy was higher with the nylon guide (3.8mm) versus the conventional guide (5.7mm).
Conclusions:
- The single-use, size-specific nylon guide demonstrated superior accuracy and precision in anteversion and insertion point compared to conventional guides in a synthetic bone model for hip resurfacing arthroplasty.
- The findings suggest potential benefits for using single-use guides in other orthopaedic procedures.
- This innovation may lead to improved outcomes in arthroplasty surgery.
Related Concept Videos
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
Bioavailability Study Design: Single Versus Multiple Dose Studies
Brick Sizes
Modular bricks are the most common type and are sized to include the mortar joint, which is essential for...
Genome Size and the Evolution of New Genes
Maximum Size of Aggregate
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...