Related Experiment Video
Updated: Jan 26, 2026

Validating Whole Genome Nanopore Sequencing, using Usutu Virus as an Example
Published on: March 11, 2020
Nano-GLADIATOR: real-time detection of copy number alterations from nanopore sequencing data
Alberto Magi1, Davide Bolognini2, Niccoló Bartalucci3
1Department of Information Engineering, University of Florence, Florence, Italy.
Motivation:
The past few years have seen the emergence of nanopore-based sequencing technologies which interrogate single molecule of DNA and generate reads sequentially.
Results:
In this paper, we demonstrate that, thanks to the sequentiality of the nanopore process, the data generated in the first tens of minutes of a typical MinION/GridION run can be exploited to resolve the alterations of a human genome at a karyotype level with a resolution in the order of tens of Mb, while the data produced in the first 6-12 h allow to obtain a resolution comparable to currently available array-based technologies, and thanks to a novel probabilistic approach are capable to predict the allelic fraction of genomic alteration with high accuracy. To exploit the unique characteristics of nanopore sequencing data we developed a novel software tool, Nano-GLADIATOR, that is capable to perform copy number variants/alterations detection and allelic fraction prediction during the sequencing run ('On-line' mode) and after experiment completion ('Off-line' mode). We tested Nano-GLADIATOR on publicly available ('Off-line' mode) and on novel whole genome sequencing dataset generated with MinION device ('On-line' mode) showing that our tool is capable to perform real-time copy number alterations detection obtaining good results with respect to other state-of-the-art tools.
Availability And Implementation:
Nano-GLADIATOR is freely available at https://sourceforge.net/projects/nanogladiator/.
Supplementary Information:
Supplementary data are available at Bioinformatics online.
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Altered States of Awareness
The ingestion of substances like stimulants or hallucinogens leads to chemical alterations in the brain...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Cis-regulatory Sequences
How Data are Classified: Numerical Data
Quantitative data may be either discrete or continuous. All quantitative data that take on only specific numerical...

