Discrete sampling based-flow injection as an introduction system in ICP-MS for the direct analysis of low volume
María Pilar Chantada-Vázquez1, Paloma Herbello-Hermelo1, Pilar Bermejo-Barrera1
1Trace Element, Spectroscopy and Speciation Group (GETEE), Strategic Grouping in Materials (AEMAT), Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n, 15782 Santiago de Compostela, Spain.
Abstract:
Discrete sampling based on the flow injection options offered by advanced autosamplers has been tested and applied for the direct analysis of low volume samples (human serum) for multi-elemental purposes (simultaneous Al, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Ni, Pb, Rb, Se, V, and Zn assessment). Serum samples (200 µL aliquots) were directly diluted to 2.0 mL with 1% (v/v) HNO3, and discrete sampling operating conditions were optimized to allow cleaning, loading (300 µL injection loop), and measuring steps by using a volume lower than 2.0 mL (diluted serum sample). Matrix effect has been overcome by using the standard addition technique, and accurate results implied the use of kinetic energy discrimination (KED) mode (He as a collision gas) for measurements. The proposed method has been found to be reliable for serum samples analysis because of the low sample volume requirements, the minimal sample preparation required, and high sampling rate (each replicate analysis takes 2.50 min). In addition, validation results show good precision and accuracy (both analytical recovery and analysis of certified reference materials), and acceptable sensitivity. Applicability of the proposed method has been finally demonstrated by analysing several serum samples from healthy adults.
More Related Videos
10:19High-throughput Flow Cytometry Cell-based Assay to Detect Antibodies to N-Methyl-D-aspartate Receptor or Dopamine-2 Receptor in Human Serum
Published on: November 23, 2013
06:53Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Sampling Theorem
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2....