Related Experiment Video
Updated: Jan 26, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Real-Time Simulator based hybrid control of DFIG-WES
Kiran Kumar Jaladi1, K S Sandhu1
1Electrical Engineering Department, National Institute of Technology Kurukshetra, 136119, India.
Abstract:
This paper presents the analysis and design of recurrent neural network (RNN) and proportional and integral(PI) controller based hybrid control(HC) of doubly fed induction generator (DFIG). The proposed HC shows the quick dynamic and good transient response during the sudden changes in wind speed as well as generator speed. Further performance of proposed hybrid controller has been analyzed independently with RNN and PI control as its components. The HC along with RNN gives effective performance compared to conventional DTC (CDTC) and PI DTC in terms of flux ripples,torque ripples and settling time. The proposed technique is implemented in real-time simulator (RTS) based OPAL-RT and MATLAB/SIMULINK environment at a rating of 5.5 KW system under steeply and randomly change in wind velocity.