Related Experiment Video
Updated: Jan 26, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
One step bulk modification of poly(L-lactic acid) composites with functional additives to improve mechanical and
Eun Young Kang1, Bogyu Choi2, Wooram Park2
1Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam, Gyeonggi 13488, Republic of Korea; College of Life Sciences Biotechnology, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
Abstract:
Poly(L-lactic acid) (PLLA) has been widely used as a promising biomaterial in biomedical applications due to its biodegradability and high mechanical strength. However, because of the inherent brittleness, low impact resistance, and weak thermal stability of PLLA, the modification process is usually required to utilize it for biomedical devices. Furthermore, acidic byproducts resulting from the hydrolysis of PLLA after implantation reduce the pH of the surrounding environment and cause inflammatory responses in the implanted area, leading to the failure of their clinical applications. To this end, here, we demonstrate a novel modification process for the PLLA composite with various functional additives, such as cis-aconitic anhydride (AA), triacetin (TA), isosorbide derivative (ISB), and/or Pluronic® F127 (F). The modified PLLA composite with TA and F (PLLA/TF) showed significantly improved elongation at break and Young's modulus and retained tensile strength. Moreover, incorporating magnesium hydroxide (MH) nanoparticles (PLLA/TFMH) significantly reduced acid-induced inflammation responses caused by the acidic degradation products of PLLA. Reduced plasma protein adsorption was observed in the PLLA/TFMH. These results suggest that the one step bulk modification of biodegradable PLLA using TA, F, and MH will have great potential in cardiovascular implant applications.
Related Concept Videos
Composition of Polyprotic Acid Solutions as a Function of pH
A graph with the alpha values is plotted against the volume of...
Nucleophilic Addition to the Carbonyl Group: General Mechanism
A stronger nucleophile can directly attack the electrophilic center, the carbonyl carbon. The HOMO orbital of the nucleophile interacts with the LUMO (π* antibonding) orbital present on the carbonyl carbon. This interaction breaks the π bond and shifts the π...
Mechanical Protein Functions
Histone Modification
Acetylation
The enzyme histone acetyltransferase adds acetyl group to the histones. Another enzyme, histone...
Applications Of NMR In Biology
Acid-Catalyzed Aldol Addition Reaction

