Related Experiment Video
Updated: Jan 26, 2026

Temporomandibular Joint Pain Measurement by Bite Force and Von Frey Filament Assays in Mice
Published on: September 13, 2024
Masticatory function and bite force of mandibular single-implant overdentures and complete dentures: a randomized
Thuy Lam Vo1, Manabu Kanazawa1, Khaing Myat Thu1
1Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
Single-implant overdentures (IODs) significantly improve mixing ability (MA), comminuting ability (CA), and maximum bite force (MBF) compared to conventional complete dentures (CDs). IODs offer superior restoration of mandibular function for edentulous patients.
Area of Science:
- Dental prosthetics
- Biomaterials science
- Oral rehabilitation
Background:
- Complete dentures (CDs) often provide suboptimal restoration of oral functions.
- Edentulism significantly impacts masticatory performance and bite force.
- Single-implant overdentures (IODs) are a potential alternative for improving function.
Purpose of the Study:
- To compare the mixing ability (MA), comminuting ability (CA), and maximum bite force (MBF) of single-implant overdentures (IODs) versus complete dentures (CDs).
- To evaluate the efficacy of IODs in restoring masticatory function in edentulous mandibles.
- To assess the functional differences between new and old CDs and IODs.
Main Methods:
- A randomized crossover control trial was conducted with 22 edentulous patients.
- Patients received either an IOD or a new CD for 2 months, followed by a crossover period.
- MA, CA, and MBF were measured using existing CDs, newly fabricated CDs, and IODs.
Main Results:
- IODs demonstrated significantly higher MA, CA, and MBF compared to both old and new CDs (p < 0.01).
- New CDs showed a significant improvement only in MA (p < 0.05) over old CDs.
- No significant differences were found in CA and MBF between old and new CDs.
Conclusions:
- Single-implant overdentures are more effective than complete dentures in restoring masticatory function.
- IODs significantly enhance mixing ability, comminuting ability, and maximum bite force.
- For edentulous mandibles, IODs provide superior functional rehabilitation compared to conventional CDs.
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Transfer Function in Control Systems
To derive the transfer function, consider a general nth-order linear time-invariant...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...

