Related Experiment Video
Updated: Jan 26, 2026

A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019
A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External
Benjamin Kerzner1, Hannah L Martin2, Michael Weiser1
1Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison.
Abstract:
Orthopedic research relies heavily on animal models to study mechanisms of bone healing in vivo as well as investigate the new treatment techniques. Critical-sized segmental defects are challenging to treat clinically, and research efforts could benefit from a reliable, ambulatory small animal model of a segmental femoral defect. In this study, we present an optimized surgical protocol for the consistent and reproducible creation of a 5 mm critical diaphyseal defect in a rat femur stabilized with an external fixator. The diaphyseal ostectomy was performed using a custom jig to place 4 Kirschner wires bicortically, which were stabilized with an adapted external fixator device. An oscillating bone saw was used to create the defect. Either a collagen sponge alone or a collagen sponge soaked in rhBMP-2 was implanted into the defect, and the bone healing was monitored over 12 weeks using radiographs. After 12 weeks, rats were sacrificed, and histological analysis was performed on the excised control and treated femurs. Bone defects containing only collagen sponge resulted in non-union, while rhBMP-2 treatment yielded the formation of a periosteal callous and new bone remodeling. Animals recovered well after implantation, and external fixation proved successful in stabilizing the femoral defects over 12 weeks. This streamlined surgical model could be readily applied to study bone healing and test new orthopedic biomaterials and regenerative therapies in vivo.
Related Concept Videos
Reliability and Validity
RNA Stability
Genome Size and the Evolution of New Genes
Nuclear Stability
To hold positively charged protons together...
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...

