Test-retest reliability of a hip strength assessment system in varsity soccer players
Gauthier Desmyttere1, Sylvain Gaudet1, Mickael Begon1
1École de Kinésiologie et des Sciences de l'Activité Physique, Faculté de Médecine, Université de Montréal, Campus Laval, 1700 rue Jacques Tétreault, Laval, QC, H7N 0B6, Canada.
Objective:
To investigate test-retest reliability of a hip strength assessment system (GroinBar).
Design:
Test-retest reliability study.
Setting:
Laboratory.
Participants:
Twenty asymptomatic varsity soccer players.
Main Outcome Measures:
Maximal isometric hip strength (adduction, abduction, internal and external rotation, flexion and extension) was assessed using the GroinBar. Intraclass correlation coefficient (ICC) and relative standard error of measurement (SEM) were calculated to evaluate reliability of peak (ICC3,1) (highest peak within 3 trials) and average peak (ICC3,3) (average of 3 trials) force and rate of force development (RFD). Hotelling's T2, were also used to compare bilateral and reciprocal ratios between dominant and non-dominant leg.
Results:
ICC for both peak force and RFD values revealed moderate to good reliability (0.53-0.88 and 0.61-0.84, respectively), whereas reliability was good to excellent regarding their average values (0.77-0.95 and 0.81-0.92, respectively). SEM of average peak force and RFD values (4.1-9.4% and 8.2-13.9%, respectively) were lower than that of peak force and RFD values (5.7-13.0% and 10.7-19.1%, respectively). No significant difference was found in bilateral and reciprocal force ratios between dominant and non-dominant leg.
Conclusions:
The GroinBar is a reliable tool to assess hip muscle function in athletic populations and could be used for player screening and follow-up.
More Related Videos
06:36Biomechanical Analysis Methods to Assess Professional Badminton Players' Lunge Performance
Published on: June 11, 2019
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Related Concept Videos
Reliability and Validity
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...