Related Experiment Video
Updated: Feb 23, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
Average rotation matrices for converting scapula- and glenoid-based coordinate systems to ISB recommendations
Florent Moissenet1, Benjamin Michaud2, Pierre Puchaud3
1Kinesiology Laboratory, Geneva University Hospitals and University of Geneva, Geneva, Switzerland; Biomechanics and Translational Research in Surgery, Department of Surgery, University of Geneva, Geneva, Switzerland.
Abstract:
Defining bone-embedded local coordinate systems (LCSs) is fundamental in shoulder biomechanics, yet multiple scapular LCSs exist, hindering data comparison. Although the International Society of Biomechanics (ISB) has published recommendations, alternative definitions based on distinct anatomical landmarks remain often used. To address these inconsistencies, average rotation matrices were recently proposed to convert between the three most common scapular LCSs, thereby facilitating comparison, merging, and interoperability between datasets. Building upon this, we have extended the approach to 11 scapular LCSs reported in the literature, including scapula- and glenoid-based systems. Using statistical shape models derived from 80 participants (asymptomatic and pathological shoulders), 1000 scapulae were generated to quantify geometric transformations between LCSs. Average rotation matrices were computed for each alternative system relative to the ISB-recommended LCS, and accuracy was assessed using helical angles. The application of the average rotation matrices substantially reduced the maximal discrepancies between LCSs, from 21.9° to 5.2°. Scapula-based systems exhibited lower discrepancies than glenoid-based ones, reflecting greater morphological variability in the glenoid region. Comparisons with previously published matrices showed minimal differences (<3°), supporting the robustness of the approach across various datasets and population. These findings confirm that average rotation matrices provide a reliable means of harmonising scapular kinematic data across studies, even if experimenters initially chose a different LCS. This work offers a simple framework, for bridging existing scapular kinematic datasets and promoting interoperability datasets in shoulder biomechanics research.
Related Concept Videos
Muscles of the Shoulder
Anterior Thoracic Muscles
The anterior thoracic muscles include the serratus anterior, subclavius, and...
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
Moments of Inertia for an Area about Inclined Axes
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
Vector Transformation in Rotating Coordinate Systems

