Related Experiment Video
Updated: Jan 26, 2026

The Crossmodal Congruency Task as a Means to Obtain an Objective Behavioral Measure in the Rubber Hand Illusion Paradigm
Published on: July 26, 2013
Comparison of Fire Behaviors of Thermally Thin and Thick Rubber Latex Foam under Bottom Ventilation
Qi Yuan1, Dongmei Huang2, Yiwei Hu3
1College of Quality and Safety Engineering, China Jiliang University, Hangzhou 310018, China. solar9552@163.com.
Abstract:
Fire behaviors of rubber latex foam under different thickness conditions (d = 1, 2, and 5 cm) were explored by using a self-built small-scale experimental platform. It can be shown that the flame spread menchanism of thermally thin and thermally thick rubber latex foam is different. Rubber latex foam with a thickness of 2 cm shows higher fire risk, whose value of flame spread rate, maximum flame height, maximum mass loss rate, and maximum temperature are 2.93 × 10-3 m/s, 851.88 mm, and 1.83 g/s, 948.00 °C, respectively. On the one hand, this may due to the different mechanisms of flame spread, resulting in different preheating zones on the surface. On the other hand, this may because the thickness of residue formed by thermally thick materials is larger than the thin ones, obstructing the contact of the rubber latex foam with fresh air. In addition, a special phenomenon is noticed during the stage II, where the bottom unburned zone is located in the four edges (thermally thin material) and middle player (thermally thick material).
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...

