Related Experiment Video
Updated: Jan 26, 2026

The Establishment of a Murine Mandibular Molar Extraction Socket Healing Model
Published on: January 13, 2023
Comparative evaluation of instrumentation timing and cleaning efficacy in extracted primary molars using manual and
Rachita Mehlawat1, Rishabh Kapoor1, Kapil Gandhi1
1Department of Pedodontics & Preventive Dentistry, Inderprastha Dental College & Hospital, 46/1, Site IV, Industrial Area, Sahibabad, Ghaziabad, Uttar Pradesh, 201010, India.
Aim:
To compare the timing of instrumentation and cleaning efficacy between manual K files and NiTi rotary files in extracted primary molars.
Study Design:
in-vitro study was conducted in 90 root canals of extracted primary molars which were subdivided in three groups viz. Control (No instrumentation), Manual (K files), Rotary (ProFiles) with 30 canals in each group. Mesiobuccal (MB) and Mesiolingual (ML) canals of mandibular molars, and MB and Distobuccal (DB) canals of maxillary molars were included in the test group whereas Distal canals in mandibular molars and Palatal canals in maxillary molars were included in the control group.
Method:
Teeth were mounted and canals were injected with India ink to stain the canal walls. Canal preparation was done as per the group. After instrumentation, teeth were demounted, decalcified and cleared to make them transparent for scoring according to the extent of removal of India ink. Timing of instrumentation and cleaning efficacy of canals in coronal, middle and apical thirds were assessed in each sample.
Results:
Mean timing of instrumentation in rotary group was 3.54 ± 1.14 min and 4.32 ± 1.04 min in manual group. Mean cleaning efficacy scores in manual and rotary groups were 2.03 and 1.66 in coronal third, 1.08 and 1.18 in middle third and 0.67 and 1.08 in apical third respectively. Inter-group comparisons showed no statistically significant difference in cleaning efficacy among test groups in all thirds of root canals.
Conclusion:
NiTi rotary technique has comparable cleaning efficacy, with significantly less timing of instrumentation compared to manual K-files.
More Related Videos
Related Concept Videos
Molar Mass
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Instrument Transformers
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...