Related Experiment Video
Updated: Jan 26, 2026

Autonomously Bioluminescent Mammalian Cells for Continuous and Real-time Monitoring of Cytotoxicity
Published on: October 28, 2013
Monitoring of Microphysiological Systems: Integrating Sensors and Real-Time Data Analysis toward Autonomous
Ashlyn T Young1, Kristina R Rivera1, Patrick D Erb1
1Joint Department of Biomedical Engineering , North Carolina State University and University of North Carolina, Chapel Hill , 911 Oval Drive , Raleigh , North Carolina 27695 , United States.
Abstract:
Microphysiological systems replicate human organ function and are promising technologies for discovery of translatable biomarkers, pharmaceuticals, and regenerative therapies. Because microphysiological systems require complex microscale anatomical structures and heterogeneous cell populations, a major challenge remains to manufacture and operate these products with reproducible and standardized function. In this Perspective, three stages of microphysiological system monitoring, including process, development, and function, are assessed. The unique features and remaining technical challenges for the required sensors are discussed. Monitoring of microphysiological systems requires nondestructive, continuous biosensors and imaging techniques. With such tools, the extent of cellular and tissue development, as well as function, can be autonomously determined and optimized by correlating physical and chemical sensor outputs with markers of physiological performance. Ultimately, data fusion and analyses across process, development, and function monitors can be implemented to adopt microphysiological systems for broad research and commercial applications.
Related Concept Videos
The Integrated Rate Law: The Dependence of Concentration on Time
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Analysis of Population Pharmacokinetic Data
Autonomic Nervous System
The ANS comprises two main divisions: the sympathetic and parasympathetic divisions. These divisions function antagonistically to maintain a dynamic...