Related Experiment Video
Updated: Jan 26, 2026

Wet-spinning-based Molding Process of Gelatin for Tissue Regeneration
Published on: March 7, 2019
Effects of Processing Equipment on Howard Mold and Rot Fragment Counts of Tomato Catsup
Ruth Bandler1, Paris M Brickey1, Stanley M Cichowicz1
1Division of Microbiology, Food and Drug Administration, 200 C Street, S.W. Washington, DC. 20204.
Abstract:
Two studies were done to determine the effects of processing equipment on Howard mold and rot fragment counts of tomato catsup. In a pilot plant study in 1980, batches of catsup with known cut-out rot levels were produced and processed through various types of comminution equipment. Urschel and Fitzpatrick mills and homogenizers at 500 to 700 and 1500 to 2000 psi increased mold counts more than twofold over the range of data obtained. Contrary to previous reports, Urschel mills increased rot counts significantly. A nationwide survey was conducted in 1983 to determine if similar effects would be found with well-characterized commercial products. Data were obtained on inline and finished products from 164 lots of catsup produced at 16 plants located across the country. Urschel and Fitzpatrick mills tended to increase mold counts over twofold and caused a slight increase in rot counts. High pressure homogenizers (≥2000 psi) tended to decrease mold counts; low pressure homogenizers (<2000 psi) increased them. Homogenization at any pressure reduced rot counts dramatically. Although mold counts were highest for catsup produced in the eastern United States and lowest for catsup produced in the West, milling and low pressure homogenization were also most prevalent in the East and least prevalent in the West. When the effects of these types of comminution were removed, the difference between regions diminished. Compared with the norm, rainfall levels for the growing regions involved in this survey were fairly typical.
More Related Videos
07:06Wicking Tests for Unidirectional Fabrics: Measurements of Capillary Parameters to Evaluate Capillary Pressure in Liquid Composite Molding Processes
Published on: January 27, 2017
10:18Fragmenting Bulk Hydrogels and Processing into Granular Hydrogels for Biomedical Applications
Published on: May 17, 2022
Related Concept Videos
Habitat Fragmentation
Leveling Equipment
Personal Protective Equipment
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Handwashing I: Introduction and Types of Equipment
Hand wash basins in clinical areas should have faucets that can be turned on and off without using the hands; that is, they should be non-touch or lever-operated....