Related Experiment Video
Updated: Jan 26, 2026

Multilevel Microdissection and Functional-Structural Profiling of Human Renal Arterial Branches
Published on: September 5, 2025
Renal Artery Branch Denervation: Evaluation of Lesion Characteristics Using a Thermochromic Liquid Crystal Phantom
Sara I Al Raisi1, Jim Pouliopoulos1, Michael T Barry1
1Department of Cardiology, Westmead Hospital, Sydney, NSW, Australia; University of Sydney, Sydney, NSW, Australia.
Background:
Lately, combined main vessel and branch ablation has been recommended during radiofrequency (RF) renal artery denervation. Utilising a validated renal artery phantom model, we aimed (1) to determine thermal injury extent (lesion depth, width and circumferential coverage) and electrode-tissue interface temperature for branch renal artery ablation, and (2) to compare the extent of thermal injury for branch versus main vessel ablation using the same RF System.
Methods:
We employed a gel based renal artery phantom model simulating variable vessel diameter and flow, which incorporated a temperature sensitive thermochromic-liquid-crystal (TLC) film for assessing RF ablation thermodynamics. Ablations in a branch renal artery model (n = 32) were performed using Symplicity Spyral (Medtronic, Minneapolis, MN, USA). Lesion dimensions defined by the 51 °C isotherm, circumferential injury coverage, and electrode-tissue interface temperature were measured for all ablations at 60 seconds.
Results:
Lesion dimensions were 2.13 ± 0.13 mm and 4.13 ± 0.18 mm for depth and width, respectively, involving 23% of the vessel circumference. Maximum electrode-tissue interface temperature was 68.31 ± 2.29 °C. No significant difference in lesion depth between branch and main vessel ablations was found (Δ = 0.02 mm, p = 0.60). However, lesions were wider in the branch (Δ=0.49 mm, p < 0.001) with a larger circumferential coverage compared to main vessel (arc angle of 82.02±3.27° versus 54.90±4.36°, respectively).
Conclusions:
In the phantom model, branch ablations were of similar depth but had larger width and circumferential coverage compared to main vessel ablations. Concerning safety, no overheating at the electrode-tissue interface was observed.
Related Concept Videos
Modeling of Diode Forward Characteristics
Modeling of Diode Reverse Characteristics
When a reverse voltage applied to a Zener diode exceeds its breakdown voltage, the diode enters the breakdown region. At this point, the...
Characteristics of Life
Crystal Field Theory - Octahedral Complexes
To explain the observed behavior of transition metal complexes (such as colors), a model involving electrostatic interactions between the electrons from the ligands and the electrons in the unhybridized d orbitals of the central metal atom has been developed. This electrostatic model is crystal field theory (CFT). It helps to understand, interpret, and predict the colors, magnetic behavior, and some structures of coordination compounds of transition metals.
CFT focuses on...
Ionic Crystal Structures
Most monatomic ions behave as charged spheres, and their attraction for ions of opposite charge is the same in every direction. Consequently, stable structures for ionic compounds result (1) when ions of one charge are surrounded by as many ions as possible of the opposite...
Crystal Growth: Principles of Crystallization
Initiating crystallization involves manipulating the concentration of the solute and the temperature of the solution. Since crystal growth occurs when the ratio of concentration and solubility of the solute in the solvent...

