Related Experiment Video
Updated: Jan 26, 2026

A Polyaniline-based Sensor of Nucleic Acids
Published on: November 1, 2016
Potassium Iodide-Functionalized Polyaniline Nanothin Film Chemiresistor for Ultrasensitive Ozone Gas Sensing
Sira Srinives1,2, Tapan Sarkar3,4, Raul Hernandez5
1Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA 92521, USA. sira.sri@mahidol.ac.th.
Abstract:
Polyaniline (PANI) nanostructures have been widely studied for their sensitivity to atmospheric pollutants at ambient conditions. We recently showed an effective way to electropolymerize a PANI nanothin film on prefabricated microelectrodes, and demonstrated its remarkable sensing performance to be comparable to that of a one-dimensional nanostructure, such as PANI nanowires. In this work, we report further progress in the application of the PANI nanothin film chemiresistive sensor for the detection of ozone (O₃) by modifying the film with potassium iodide (KI). The KI-PANI sensor exhibited an excellent sensitivity to O₃ (8⁻180 ppb O₃ concentration rage) with a limit of detection of 230 ppt O₃, and exquisite selectivity against active chemicals such as nitrogen dioxide (NO₂) and sulfur dioxide (SO₂). The sensing mechanism of the sensor relied on iodometric chemistry of KI and O₃, producing triiodide ( I 3 - ) that partially doped and increased electrical conductivity of the PANI film. The sensitivity and selectivity of the KI-functionalized PANI film demonstrates the potential use for KI-PANI-based O₃ sensing devices in environmental monitoring and occupational safety.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Related Concept Videos
Regulation of Sodium and Potassium
Sodium Regulation
Sodium ions make up approximately 90% of extracellular cations, with a normal blood plasma concentration of 136–148 mEq/L. A decrease in blood volume and pressure triggers the release of renin from granular cells in the juxtaglomerular complex (JGC), primarily...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Gas Exchange and Transport
Kinetic Molecular Theory and Gas Laws Explain Properties of Gas Molecules
Gas Laws: Boyle's, Gay-Lussac, Charles', Avogadro's, and Ideal Gas Law
Roles of Electrolytes: Sodium and Potassium