Impact of calibration methods for color medical displays on interpreting brain SPECT images
Takayuki Shibutani1, Masahisa Onoguchi1, Hiroto Yoneyama2
1Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Ishikawa, 920-0942, Japan.
Purpose:
Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color images is γ2.2, but it has not been standardized. The color standard display function (CSDF) has recently been proposed as a standardized gamma setting for color medical monitors. However, the influence of various gamma settings on image characteristics should be determined. The present study aimed to identify differences in color-scale characteristics on nuclear medicine images displayed on medical monitors adjusted by CSDF, GSDF, and γ2.2.
Methods:
Transverse normal (n = 1) and abnormal (n = 5) brain perfusion images were generated using a mathematical digital phantom. Transverse phantom and clinical brain images are shown using the clinically applied eight-color scale. Five nuclear medicine experts visually assessed phantom and clinical images using a defect severity scale that ranged from zero (no defect) to four (defect). Receiver operating characteristic curves were created and areas under the curves (AUCs) were analyzed. Defect scores for the clinical study were evaluated in the nine segments on basal ganglia slice, and defect scores were summed for each patient.
Results:
The average defect score for color A significantly differed in multiple comparison tests, but not in post hoc tests. The ranges of AUC for CSDF, GSDF, and γ2.2 were 0.86-0.94, 0.82-0.94, and 0.88-0.97, respectively. The AUCs of CSDF in all color scales did not significantly differ from other gamma settings. The summed defect scores of CSDF were similar to those of other gamma settings.
Conclusion:
Nuclear medicine images were equally valid when adjusted by CSDF even at various gamma settings. Nuclear medicine images can be evaluated equally using any gamma setting. Nonetheless, the color gamma setting for medical monitors should be standardized.
Related Concept Videos
Empirical Method to Interpret Standard Deviation
This rule is used widely in statistics to calculate the proportion of data values...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Color Vision
Interpreting R Charts
An R chart plots the range of subsets of measurements collected from a process. Each point on the chart represents the range—defined as the difference between the maximum and minimum...