Related Experiment Video
Updated: Jan 26, 2026

Fabrication of Silica Ultra High Quality Factor Microresonators
Published on: July 2, 2012
Factors for Consideration in an Open-Flame Test for Assessing Fire Blocking Performance of Barrier Fabrics
Shonali Nazaré1, William M Pitts2, John Shields3
1Fire Research Division, Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-8665, USA. Shonali.nazare@nist.gov.
Abstract:
The main objective of the work reported here is to assess factors that could affect the outcome of a proposed open flame test for barrier fabrics (BF-open flame test). The BF-open flame test characterizes barrier effectiveness by monitoring the ignition of a flexible polyurethane foam (FPUF) layer placed in contact with the upper side of the barrier fabric, exposed to a burner flame from below. Particular attention is given to the factors that influence the ignitibility of the FPUF, including thermal resistance, permeability, and structural integrity of the barrier fabrics (BFs). A number of barrier fabrics, displaying a wide range of the properties, are tested with the BF-open flame test. Visual observations of the FPUF burning behavior and BF char patterns, in addition to heat flux measurements on the unexposed side of the barrier fabrics, are used to assess the protective performance of the BF specimen under the open flame test conditions. The temperature and heat transfer measurements on the unexposed side of the BF and subsequent ranking of BFs for their thermal protective performance suggest that the BF-open flame test does not differentiate barrier fabrics based on their heat transfer properties. A similar conclusion is reached with regard to BF permeability characterized at room temperature. However, the outcome of this BF-open flame test is found to be heavily influenced by the structural integrity of thermally degraded BF. The BF-open flame test, in its current form, only ignited FPUF when structural failure of the barrier was observed.
Related Concept Videos
Factors Affecting Drug Distribution: Physiological Barriers
The capillary endothelial barrier allows only smaller molecules below 600 Da (Daltons) to pass through. It also restricts drugs like heparin that are bound to blood components, limiting their movement within the bloodstream.
The...
Flame Photometry: Overview
Flame Photometry: Lab
Design Consideration
The factor of safety is another key...
Transcription Factors
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...

