Related Experiment Video
Updated: Jan 26, 2026

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
Published on: May 23, 2025
Open Meniscal Allograft Transplantation With Transosseous Suture Fixation of the Meniscal Body Significantly
Gergo Merkely1, Takahiro Ogura2, Jakob Ackermann3
1Cartilage Repair Center, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, U.S.A.; Department of Traumatology, Semmelweis University, Budapest, Hungary.
Purpose:
To assess and compare meniscal extrusion rates after lateral "bridge-in-slot" meniscal allograft transplantation (MAT) with arthroscopic versus open insertion.
Methods:
In this review of prospectively collected data, we analyzed data from patients who underwent arthroscopic or open lateral MAT. Patients who underwent concomitant distal femoral osteotomy, for whom 1-year postoperative magnetic resonance imaging was unavailable, or who underwent open lateral MAT without the use of transosseous sutures were excluded. Meniscal extrusion in the included patients was assessed by 2 independent examiners by measuring the absolute value and the relative percentage of extrusion on 1.5-T magnetic resonance images at 1-year follow-up. The number of MATs with radial displacement larger or smaller than 3 mm was determined.
Results:
A total of 20 patients met the inclusion criteria, of whom 10 underwent arthroscopic and 10 underwent open lateral MAT. No statistically significant differences were found in baseline demographic data. Absolute meniscal extrusion was similar between the groups (P = .091). A significantly larger relative percentage of extrusion (arthroscopic MAT, 31 ± 27 mm; open MAT, 10 ± 29 mm; 95% confidence interval, -0.4 to -0.02 mm; P = .03) and a significantly higher extrusion rate were found in patients treated with arthroscopic MAT than in those treated with open MAT (>3 mm in 5 patients [50%] with arthroscopic MAT and 0 patients with open MAT, P = .01).
Conclusions:
This study identified similar absolute extrusion and significantly lower postoperative lateral meniscal extrusion rates after open MAT compared with arthroscopic MAT. Transosseous fixation of the meniscal body appears protective against meniscal extrusion after MAT.
Level Of Evidence:
Level III, case-control study.
Related Concept Videos
Decreased pulse rate
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
Decreased Body Temperature
Decreasing Function
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...