Related Experiment Video
Updated: Jan 26, 2026

Scalable Syntheses of Graphene Oxide and Reduced Graphene Oxide using Cascade Design Oxidation and Highly Basic Reduction Reactions
Published on: July 3, 2025
Flexible electrical aptasensor using dielectrophoretic assembly of graphene oxide and its subsequent reduction for
Abhinav Sharma1, Jaesung Jang2,3
1School of Materials Science and Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, South Korea.
Abstract:
Cardiac troponin T (cTnT) is considered a clinical standard for its high specificity and sensitivity when diagnosing acute myocardial infarction; however, most studies on the electrical sensors of cardiac troponin biomarkers have focused on cTnI rather than cTnT. This study presents label-free, low-cost, transparent, and flexible aptamer-based immunosensors for the electrical detection of cTnT using reduced graphene oxide (rGO) sheets. GO was first deposited by AC dielectrophoresis between two predefined source and drain electrodes on a 3-aminopropyltriethoxylsilane-modified polyethylene terephthalate substrate. The GO was then reduced using hydrazine vapour without damaging the substrate, resulting in uniform, controlled, and stable deposition of rGO sheets, and demonstrating more stability than those directly deposited by dielectrophoresis. Amine-modified single-strand DNA aptamers against cTnT were immobilized onto the rGO channels. The relative resistance change of this sensor owing to the attachment of cTnT was quantified as the cTnT concentration decreased from 10 ng/mL to 1 pg/mL in phosphate buffered saline (PBS) and 10-fold diluted human serum in PBS, with the limits of detection being 1.2 pg/mL and 1.7 pg/mL, respectively, which is sufficiently sensitive for clinical applications. High-yield and rapid fabrication of the present rGO sensors will have significant influences on scaled-up fabrication of graphene-based sensors.
Related Concept Videos
Oxidation-Reduction Reactions
Oxidation and Reduction of Organic Molecules
The removal of an electron from a molecule, results in a...
Reactions at the Benzylic Position: Oxidation and Reduction
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Oxidation Numbers
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...