Lower creatinine concentration values and lower inter-laboratory variation among Swedish hospital laboratories in
Johanna Helmersson-Karlqvist1, Peter Ridefelt1, Elisabet Eriksson Boija2
1Department of Medical Sciences, Clinical Chemistry, Uppsala University Hospital, Uppsala, Sweden.
Abstract:
Background Creatinine measurement for estimation of glomerular filtration rate (GFR) is a frequently used laboratory test. Differences in analytic creatinine methods have caused large inter-laboratory variation. International and national standardization efforts have been made in the last decade. Methods This study describes the results of the standardization efforts in Sweden by summarizing data for creatinine concentration in blood plasma in the Equalis quality assessment program during 1996-2014. Results Non-compensated Jaffe methods dominated in 1996-2001 (91 of 103 laboratories; 90%) and were then gradually replaced by either compensated Jaffe methods or enzymatic creatinine methods. In 2014 a majority of Swedish hospital laboratories (139 of 159; 87%) used enzymatic methods. The reported mean creatinine value by the Swedish laboratories was about 10 μmol/L higher than the isotope dilution mass spectrometry (IDMS) assured reference value in 2003, but consistent with the reference value from 2009 to 2014. The inter-laboratory CV was 7%-9% for creatinine values until 2007, and thereafter gradually decreased to about 4%-5% in 2014. Conclusions The introduction of enzymatic methods in Swedish laboratories has contributed to achieving a low inter-laboratory variation. Also, the reported values are lower for enzymatic methods compared to Jaffe methods, and the values obtained with enzymatic methods were consistent with IDMS certified values established at reference laboratories. Thus, many Swedish hospital laboratories reported 10 μmol/L lower, and more true, creatinine concentrations in 2012 than in 2003, which may cause bias in longitudinal studies.
More Related Videos
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
07:08Nanoparticle Tracking Analysis of Gold Nanoparticles in Aqueous Media through an Inter-Laboratory Comparison
Published on: October 20, 2020
Related Concept Videos
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Hospitals-II
Nurses that work in...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Hospitals-I
Serum Laboratory Studies, Stool Test, Breath Test
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration