Measurement of cerebral vascular reserves with I-123 IMP SPECT without an arterial input function using the
Sunao Mizumura1, Satoshi Iwabuchi2, Satoshi Fujita2
1Department of Radiology, Toho University, Medical Centre Omori, 6-11-1, Omori-nishi, Ota-ku, Tokyo, 143-8541, Japan. sunaom@med.toho-u.ac.jp.
Objectives:
Cerebral vascular reserve (CVR) is an important indicator for the management of and therapy for cerebral arterial occlusive disease (CAOD). Vasodilatory function is measured using the standard IMP-ARG method. The IMP autoradiography (IMP-ARG) method employed here uses a standardized input function, which was derived from 12 patients between 31 and 71 years of age. Because the population of elderly patients continues to increase in Japan, additional therapies are required to assess CVR in elderly patients with chronic cardiopulmonary disease or a history of smoking, in particular. Despite its popularity, alternatives to the IMP-ARG method are necessary. Here, we proposed the microsphere (MS) method without an input function.
Method:
Using this method and the IMP-ARG method, we measured the CVRs of 18 CAOD patients.
Results:
The CVRs derived with these two methods were significantly and linearly correlated (r = 0.89, p < 0.01). CVRs categorized by severity were also found to correspond between the two methods (κ = 0.87).
Conclusions:
Thus, the method proposed here may serve as a supplemental to and be compatible with the IMP-ARG method for the assessment of CVR. Furthermore, the two methods, when used in conjunction, may result in less error than either would alone.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
06:10A Rat Model of Middle Cerebral Artery Occlusion/Reperfusion Without Damaging the Anatomical Structure of Cerebral Vessels
Published on: May 17, 2024
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Dose Size and Dosing Frequency: Determination Methods
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Calibration Curves: Correlation Coefficient