Determination of adsorbable organically bound fluorine (AOF) and adsorbable organically bound halogens as sum
Eleonora von Abercron1, Sandy Falk1, Thorsten Stahl2
1Hessian State Laboratory, Glarusstrasse 6, D-65203 Wiesbaden, Germany.
Abstract:
Because of their toxicity and biomagnification potential individual perfluoroalkyl and polyfluoroalkyl substances (PFAS) are regularly examined in food and environmental matrices by LC-MS/MS. The combustion ion chromatography (CIC) can be used to determine adsorbable organic fluorine (AOF) in aqueous samples. This report describes the optimization and validation of an automated, robust, cost-efficient and rapid CIC method for the determination of AOF. The analysis of 25 fluorinated organic reference substances was performed with recoveries between 16% and 121%. Water from selected surface waters (n = 74), municipal (n = 116) and industrial wastewaters (n = 33) as well as ground water (n = 93) were analyzed by means of CIC. The AOF values of surface water varied between 2.3 and 24.5 μg/L. The concentrations of AOF in 85% of the wastewater discharges were between 2.0 and 8.5 μg/L, while 15% of the samples were below the limit of quantitation (LOQ = 2 μg/L AOF). In 56% of the ground water samples the values were below the LOQ. In 44% of the surface water samples (n = 41) the values were between 2.0 and 6.1 μg/L AOF. CIC analysis was performed in 22 samples from a chemical company wastewater treatment plant, and 14 individual PFAS were determined by LC-MS/MS. AOF values up to 555 μg/L were found in these samples while the total of the individual PFAS, calculated as fluorine, was 8.8 μg/L. This provides evidence, that CIC covers a huge range of fluoroorganic compounds that are presently not detected by LC-MS/MS. Furthermore, the CIC method allowed the determination of four halogens in 26 surface water samples. This demonstrated that the CIC technique can be used as a powerful screening test to support LC-MS/MS methods, and is also useful to detect organic chlorine, bromine and iodine compounds (AOCl, AOBr and AOI).
More Related Videos
09:46Production and Measurement of Organic Particulate Matter in the Harvard Environmental Chamber
Published on: November 18, 2018
06:45Author Spotlight: Characterizing Porous Materials for Aiding the Development of Robust Metal-Organic Frameworks with Adsorption Behavior
Published on: March 8, 2024
Related Concept Videos
Drugs Affecting GI Tract Motility: Adsorbents as Antidiarrheal Agents
Adsorbents...
Halogens
Organic Compounds
Levels of Organization
Molecules Are Composed of Atoms, and Biomolecules Are Assembled from Molecules:
The most basic levels include atoms, molecules, and biomolecules. Atoms, the smallest unit of ordinary matter, are composed of a nucleus and electrons. Molecules...
Organization of Genes
Accessory Organs