Related Experiment Video
Updated: Jan 26, 2026

A Hybrid DNA Extraction Method for the Qualitative and Quantitative Assessment of Bacterial Communities from Poultry Production Samples
Published on: December 10, 2014
Methods for Detecting Processing Temperatures of Previously Cooked Meat and Poultry Products - A Review
W E Townsend1, L C Blankenship1
1USDA-ARS, Poultry Meat Quality and Safety Research Unit, Richard B. Russell Agricultural Research Center, P.O. Box 5677. Athens, GA 30613.
Abstract:
Title 9 of the Code of Federal Regulations establishes prescribed thermal treatment for a variety of meat and poultry products. These requirements are to ensure the destruction of harmful microorganisms and viruses that cause diseases in humans and livestock. The information presented in this review provides information relative to the current procedures used by the Food Safety and Inspection Service (FSIS) for monitoring the adequacy of heat treatment of meat and poultry products; and the research activities that have been and are currently being conducted to develop new and/or improved methods for determining the maximum internal temperature of meat and poultry products. Currently, FSIS is using a protein "Coagulation Test" for monitoring the maximum internal temperature (MIT) of both beef and pork products heat processed to temperatures lower than 65°C; a residual "Acid Phosphatase Activity Method" for determining the MIT of canned hams, canned picnics and canned luncheon meat, and a third method, known as the "Bovine Catalase Test", for the determination of catalase which gives a pass/fail indication at a cooking temperature of 62.8°C for rare roast beef and cooked beef. Since 1957, several attempts have been made to develop new and/or improved methods. These include an evaluation of the enzyme systems and various physical techniques. The lack of new and/or improved methods is not due to the lack of research efforts in this area, as evidenced by this review. The challenge is the development of a method which can accurately determine within ± 1.0°C the endpoint temperature in the temperature range (67.8 - 70.0°C) that is of most interest to FSIS.
More Related Videos
08:19Modified Most Probable Number Assay to Quantify Salmonella in Raw and Ready-to-Cook Chicken Products
Published on: January 31, 2025
05:34Author Spotlight: Development of an Enhanced Protocol for Rapid and Accurate Isolation of Campylobacter from Food Products
Published on: February 23, 2024
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
The Scientific Method in Nursing Process
When using research findings to change practice, one must understand the process used to guide a study. The scientific method is a systematic, step-by-step process that supports the data's validity, reliability, and generalizability. As a result, findings can be...
Physical Methods for Controlling Microbial Growth: Temperature
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Temperature Dependence on Reaction Rate
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...