Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Decreasing Function01:27

Decreasing Function

250
A decreasing function describes a relationship where the output consistently declines as the input increases. This means that for any two input values, if one is greater than the other, the corresponding output is smaller. Mathematically, a function f is decreasing on an interval I if for every x1 < x2​ in I, f (x1) > f (x2). This type of behavior is visually identified on a graph that slopes downward from left to right.The nature of a function can be analyzed by calculating...
250
Decreased Body Temperature01:29

Decreased Body Temperature

1.0K
A decreased body temperature can occur in patients with hypothermia and frostbite. Heat loss with extended cold exposure overpowers the body's ability to create heat, resulting in hypothermia. Core temperature readings help classify hypothermia. Mild hypothermia is temperatures between 32 °C (89.6 °F) and 35°C (95 °F) and is caused by impaired thermoregulation. Moderate hypothermia is temperatures between 28 C (82.4 °F) and 32 °C (89.6 °F) caused by...
1.0K
Decreased pulse rate01:14

Decreased pulse rate

864
Bradycardia is a medical condition in which the heart rate is slower than normal. It occurs when the heart's natural pacemaker, the sinus node, generates slower electrical impulses than the standard rhythm. In adults, bradycardia is diagnosed when the pulse rate falls below 60 beats per minute, indicating a deviation from the normal heart rate range.
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
864
Dosage Regimen Designs: Nomograms and Tabulations01:23

Dosage Regimen Designs: Nomograms and Tabulations

190
Nomograms and tabulations are vital tools used by clinicians to design accurate and individualized dosage regimens. These instruments provide a straightforward method for adjusting dosages based on individual patient characteristics, including age, weight, and physiological condition. The foundation of a drug's nomogram is population pharmacokinetic data collected and analyzed using specific models. This data simplifies complex equations, presenting them diagrammatically or tabularly for easy...
190
Buffer Effectiveness02:19

Buffer Effectiveness

55.0K
Buffer solutions do not have an unlimited capacity to keep the pH relatively constant . Instead, the ability of a buffer solution to resist changes in pH relies on the presence of appreciable amounts of its conjugate weak acid-base pair. When enough strong acid or base is added to substantially lower the concentration of either member of the buffer pair, the buffering action within the solution is compromised.
The buffer capacity is the amount of acid or base that can be added to a given volume...
55.0K
Muscles of the Eye01:20

Muscles of the Eye

4.1K
The muscles of the eye are sophisticated structures that control eye movement and focus, allowing for the precise and rapid adjustments necessary for vision. The human eye is controlled by ten muscles — six extraocular muscles, three intraocular muscles, and one primary eyelid retractor muscle.
Extraocular Muscles
The six extraocular muscles surround the eyeball and control its movements. They are responsible for a wide range of eye motions, including looking up, down, left, right, and...
4.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Population-based study on the epidemiology of dry eye disease and its association with presbyopia and other risk factors.

International ophthalmology·2019
Same author

3-D localization of Diabetic Macular Edema using OCT thickness maps.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2016
Same author

MyBioNet: interactively visualize, edit and merge biological networks on the web.

Bioinformatics (Oxford, England)·2011
Same author

Understanding lignin-degrading reactions of ligninolytic enzymes: binding affinity and interactional profile.

PloS one·2011
Same author

[The expression and significance of Notch1 in the human kidney tubular cell transdifferentiation induced by TGF-β(1);].

Xi bao yu fen zi mian yi xue za zhi = Chinese journal of cellular and molecular immunology·2011
Same author

Construction of microRNA- and microRNA*-mediated regulatory networks in plants.

RNA biology·2011

Related Experiment Video

Updated: Jan 26, 2026

Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery
05:19

Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery

Published on: December 1, 2023

1.6K

Utilizing intraoperative aberrometry and digital eye tracking to develop a novel nomogram for manual astigmatic

Ming Chen1, Michael Reinsbach2, Nathan D Wilbanks3

  • 1Department of Surgery, Division of Ophthalmology, John A Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA.

Taiwan Journal of Ophthalmology
|April 18, 2019
PubMed
Summary

A new nomogram using intraoperative aberrometry (ORA) and digital eye tracking (VERION) improved mild astigmatism correction after cataract surgery compared to traditional methods. This enhancement offers better visual acuity and refractive outcomes.

Keywords:
Astigmatismimage-guided systeminterferometermanual astigmatic keratotomyphacoemulsification

More Related Videos

Intraoperative Ultrasound in Spinal Surgery
05:53

Intraoperative Ultrasound in Spinal Surgery

Published on: August 17, 2022

5.3K
Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
04:59

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation

Published on: July 7, 2023

3.0K

Related Experiment Videos

Last Updated: Jan 26, 2026

Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery
05:19

Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery

Published on: December 1, 2023

1.6K
Intraoperative Ultrasound in Spinal Surgery
05:53

Intraoperative Ultrasound in Spinal Surgery

Published on: August 17, 2022

5.3K
Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
04:59

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation

Published on: July 7, 2023

3.0K

Area of Science:

  • Ophthalmology
  • Refractive Surgery

Background:

  • Manual astigmatic keratotomy (MAK) is used for astigmatism correction.
  • Enhancing mild astigmatism post-cataract surgery can be challenging.
  • Intraoperative aberrometry (ORA) and digital eye tracking (VERION) offer advanced guidance.

Purpose of the Study:

  • To develop and validate a novel nomogram for MAK enhancement using ORA and VERION.
  • To compare outcomes of MAK with ORA/VERION assistance versus a traditional nomogram.

Main Methods:

  • Retrospective comparative study of 120 cataract surgery cases.
  • Sixty cases utilized MAK with ORA/VERION for astigmatism enhancement.
  • Sixty control cases used a traditional nomogram without ORA/VERION.
  • Alpins vector analysis was used for outcome comparison.

Main Results:

  • The ORA/VERION group showed a higher proportion of patients with residual cylinder <0.5 D (87% vs. 70%).
  • Better than 20/25 best-corrected visual acuity was achieved more frequently in the ORA/VERION group.
  • The novel nomogram demonstrated improved refractive outcomes.

Conclusions:

  • A novel nomogram incorporating ORA/VERION shows potential for superior astigmatism correction enhancement.
  • Further prospective studies are needed to validate these findings.
  • This nomogram may benefit surgeons without ORA/VERION if validated.