Related Experiment Video
Updated: Jan 26, 2026

Handheld Metal Detector Screening for Metallic Foreign Body Ingestion in Children
Published on: September 11, 2018
Intralenticular foreign body: A case report and literature review
Yen-Chun Lin1, Chin-Liang Kuo1, Yan-Ming Chen1,2
1Department of Ophthalmology, E-Da Hospital, I-Shou University, Kaohsiung, Taiwan.
Abstract:
The purpose of this manuscript was to provide a better understanding of patients with intralenticular foreign bodies (FBs) and also to review the reported cases, including clinical presentation, diagnosis, management, and visual outcome. A 50-year-old male was referred to our clinic with suspected intraocular FB. Under slit-lamp examination, a full-thickness corneal wound with localized corneal edema at the temporal lower peri-limbal area was revealed. Seidel test did not indicate any wound leakage. The corresponding iris was depigmented, but there was no penetrating hole. The anterior chamber was deep with cells, but the lens, vitreous, and fundus were normal. B-scan ultrasonography and orbital computed tomography were performed, but no intraocular FB was detected. On the 2nd day, a zonal cortical cataract and posterior subcapsular cataract formed rapidly. Left-eye bare vision dramatically decreased from 20/100 to counting fingers. One month later, the patient received elective extracapsular cataract extraction. A fine metal thread was completely embedded in the lens; the lens and FB were removed together during the operation. The posterior capsule was not injured; an intraocular lens was implanted in the capsular bag. Two months postoperatively, left-eye vision had returned to 20/25. No adverse events were noted during the follow-up period. In addition to the case report, some 28 previously reported cases of intralenticular FB are reviewed here. Patient demographics, time and course of management, and visual outcome are all summarized and compared.
More Related Videos
04:33Spinal Hernia Repair and Cauda Equina Repositioning After Lumbar Decompression under Three-Dimensional Microscopy: A Case Report and Literature Review
Published on: November 8, 2024
08:31Candida albicans Biofilm Development on Medically-relevant Foreign Bodies in a Mouse Subcutaneous Model Followed by Bioluminescence Imaging
Published on: January 27, 2015
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...