Effects of Prostatic Artery Embolization on the Dynamic Component of Benign Prostate Hyperplasia as Assessed by
André Moreira de Assis1,2, Airton Mota Moreira3,4, Francisco Cesar Carnevale3,4
1Interventional Radiology Department, Radiology Institute, University of Sao Paulo Medical School, Dr. Enéas de Carvalho Aguiar Avenue, 255, Cerqueira César, São Paulo, SP, 05403-000, Brazil. andre.assis@criep.com.br.
Purpose:
To determine the effects of prostatic artery embolization (PAE) on prostatic elasticity as assessed by Ultrasound Elastography (US-E), as well as to describe the feasibility and role of US-E as a novel tool in both pre- and post-PAE evaluation.
Materials And Methods:
This is a prospective, single-center investigation that included eight patients undergoing PAE for treatment of lower urinary tract symptoms (LUTS) attributed to benign prostate hyperplasia (BPH). Baseline and 3-month follow-up evaluations were performed and included prostate-specific antigen (PSA), uroflowmetry, pelvic magnetic resonance imaging and clinical assessment using the International Prostate Symptom Score (IPSS) questionnaire and the IPSS-Quality of life (QoL) item. US-E with measurement of the prostatic Elastic Modulus (EM) was performed before PAE and at 1-month follow-up.
Results:
After PAE, US-E showed a significant reduction of prostatic EM as assessed in kPa (33.14 vs. 47.24, - 29.8%, p = 0.002) and in m/s (3.75 vs. 4.63, - 19.0%, p < 0.001). Also, the transitional/peripheral zone ratio was significantly reduced by 45.36% (0.53 vs. 0.97, p < 0.05). All eight patients presented with significant LUTS improvement after PAE (p < 0.05 for IPSS, QoL, prostate volume, peak urinary flow rate and PSA).
Conclusions:
Findings described in this study suggest that PAE significantly reduces prostatic EM, leading to a positive effect on BPH dynamic component related to prostatic elasticity. Also, it features US-E as an additional tool for pre- and post-PAE evaluation, describing a novel indication for this technology.
More Related Videos
06:04Surgical Treatment for Benign Prostatic Hyperplasia: Holmium Laser Enucleation of the Prostate HoLEP.
Published on: March 6, 2018
08:38Renal Capsule Xenografting and Subcutaneous Pellet Implantation for the Evaluation of Prostate Carcinogenesis and Benign Prostatic Hyperplasia
Published on: August 28, 2013
Related Concept Videos
Pilot and Numeric Relaying
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulmonary Embolism I: Introduction
Resistors In Series
In a series circuit, the...
Series Resonance
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...