Related Experiment Video
Updated: Jan 26, 2026

Training Persons with Spinal Cord Injury to Ambulate Using a Powered Exoskeleton
Published on: June 16, 2016
Reliability and validity of the function in sitting test among non-ambulatory individuals with spinal cord injury
Libak Abou1, JongHun Sung1, Jacob J Sosnoff1
1Department of Kinesiology and Community Health, College of Applied Health Sciences, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.
Abstract:
Context: Trunk impairment among non-ambulatory individuals with spinal cord injury (SCI) reduces the ability to maintain a functional sitting position and perform activities of daily living. Measuring functional sitting balance is complex and difficult in a clinical setting. The function in sitting test (FIST) is a clinical measure that includes the assessment of all the components of sitting balance. The purpose of this study is to assess the reliability and validity of the 14-item FIST among non-ambulatory individuals with SCI. Participants: Twenty-six individuals with chronic SCI. Outcome measures: Participants were evaluated with the FIST, the modified Functional Reach Test (lateral and forward mFRT) and a posturography assessment (virtual time to contact - VTC). The FIST was re-assessed during a second study visit 12 weeks later. Test-retest reliability was evaluated using intraclass coefficient correlation (ICC), the minimal detectable change (MDC) was calculated and the internal consistency reliability was assessed using Cronbach's coefficient-α. Concurrent validity of the FIST was also tested with the mFRT and the VTC. Results: Test-retest reliability was found to be excellent (ICC = 0.95) with a MDC of 4. The internal consistency was satisfactory (0.81). Moreover, the FIST correlates with the lateral mFRT (r = 0.64, P = 0.001) but not with the forward mFRT and the VTC. Conclusion: These observations provide evidence that the FIST is a reliable clinical measure with partially established validity for non-ambulatory individuals with SCI. Further studies are needed to strengthen the validity of the FIST and explore this measure in a larger sample.
More Related Videos
09:37Evaluation of Respiratory Muscle Activation Using Respiratory Motor Control Assessment RMCA in Individuals with Chronic Spinal Cord Injury
Published on: July 19, 2013
08:07Paradigms of Lower Extremity Electrical Stimulation Training After Spinal Cord Injury
Published on: February 1, 2018
Related Concept Videos
Reliability and Validity
Spinal Cord
The Spinal Cord
Spinal Cord: Information Processing
Sensory Information Processing
Sensory information processing begins at the sensory receptors located in the skin and other tissues, which detect somatic sensory stimuli such as touch, temperature, or pain. These receptors function as catalysts, initiating...
Spinal Cord: Gross Anatomy
Spinal Cord: Cross-sectional Anatomy
Gray Matter and its Components
Central to the gray matter is...