Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Characterization and Design Improvement of a Thickness-Shear Lead Zirconate Titanate Transducer for Low Frequency
Marco Zennaro1,2, Dan J O'Boy3, Premesh Shehan Lowe4
1National Structural Integrity Research Centre, Granta Park, Great Abington, Cambridge CB21 6AL, UK. marcozennaro2@gmail.com.
Abstract:
Thickness-shear transducers for guided wave testing have been used in industry for over two decades and much research has been conducted to improve the resolution and sensitivity. Due to a geometric feature of the current state-of-the art transducer, there is an out-of-plane component in the propagation direction of the fundamental shear horizontal mode which complicates the signal interpretation. In such case, complex signal processing techniques need to be used for mode discrimination to assess the structural health with higher precision. Therefore, it is important to revise the transducer design to eliminate the out-of-plane components in the propagation direction of fundamental shear horizontal mode. This will enhance the mode purity of fundamental shear horizontal mode for its application in guided wave inspection. A numerical investigation has been conducted on a 3 mm thick 2 m circular steel plate to understand the behaviour and the characteristics of the state-of-the-art thickness-shear transducer. Based on the results, it is noted that the redesigning the electrode arrangement will suppress the out-of-plane components on the propagation direction of the fundamental shear horizontal mode. With the aid of this information current state-of-the-art transducers were redesigned and tested in laboratory conditions using the 3D Laser Doppler Vibrometer. This information will aid future transducer designers improve the resolution of thickness-shear transducers for guided wave applications and reduce the weight and cost of transducer array by eliminating the need of additional transducers to suppress spurious modes.
Related Concept Videos
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The Wave Nature of Light
Design Example: Application of Archimedes' Principle
The volume of seawater displaced by the block is determined by first calculating the block's weight. This is done by multiplying the...
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Strain